@@ -4370,6 +4370,24 @@ interface and may change in the future.</para>
<entry>The flash controller has detected a short or open
circuit condition on the indicator LED.</entry>
</row>
+ <row>
+ <entry><constant>V4L2_FLASH_FAULT_UNDER_VOLTAGE</constant></entry>
+ <entry>Flash controller voltage to the flash LED
+ has been below the minimum limit specific to the flash
+ controller.</entry>
+ </row>
+ <row>
+ <entry><constant>V4L2_FLASH_FAULT_INPUT_VOLTAGE</constant></entry>
+ <entry>The input voltage of the flash controller is below
+ the limit under which strobing the flash at full current
+ will not be possible.The condition persists until this flag
+ is no longer set.</entry>
+ </row>
+ <row>
+ <entry><constant>V4L2_FLASH_FAULT_LED_OVER_TEMPERATURE</constant></entry>
+ <entry>The temperature of the LED has exceeded its
+ allowed upper limit.</entry>
+ </row>
</tbody>
</entrytbl>
</row>
Descriptions for flash faluts. V4L2_FLASH_FAULT_UNDER_VOLTAGE, V4L2_FLASH_FAULT_INPUT_VOLTAGE, and V4L2_FLASH_FAULT_LED_OVER_TEMPERATURE v7 : Changed V4L2_FLASH_FAULT_UNDER_VOLTAGE description Signed-off-by: Daniel Jeong <gshark.jeong@gmail.com> --- Documentation/DocBook/media/v4l/controls.xml | 18 ++++++++++++++++++ 1 file changed, 18 insertions(+)