@@ -40,6 +40,7 @@
#define RC6_6A_MCE_TOGGLE_MASK 0x8000 /* for the body bits */
#define RC6_6A_LCC_MASK 0xffff0000 /* RC6-6A-32 long customer code mask */
#define RC6_6A_MCE_CC 0x800f0000 /* MCE customer code */
+#define RC6_6A_ZOTAC_CC 0x80340000 /* Zotac customer code */
#define RC6_6A_KATHREIN_CC 0x80460000 /* Kathrein RCU-676 customer code */
#ifndef CHAR_BIT
#define CHAR_BIT 8 /* Normally in <limits.h> */
@@ -246,6 +247,7 @@ static int ir_rc6_decode(struct rc_dev *dev, struct ir_raw_event ev)
switch (scancode & RC6_6A_LCC_MASK) {
case RC6_6A_MCE_CC:
case RC6_6A_KATHREIN_CC:
+ case RC6_6A_ZOTAC_CC:
protocol = RC_PROTO_RC6_MCE;
toggle = !!(scancode & RC6_6A_MCE_TOGGLE_MASK);
scancode &= ~RC6_6A_MCE_TOGGLE_MASK;
The Zotac RC2604323/01G and RC2604329/02BG remotes use the 32-bit rc6 protocol and toggle bit 15 (0x8000) on repeated button presses, like MCE remotes. Add the customer code 0x80340000 to the 32-bit rc6 toggle handling code to get proper scancodes and toggle reports. Signed-off-by: Matthias Reichl <hias@horus.com> --- LibreELEC bug report and more info are here: https://forum.libreelec.tv/thread/14388-ir-remote-malfunction-after-upgrade-to-le-9-0/