@@ -52,7 +52,7 @@
/* Analog gain control */
#define IMX335_REG_AGAIN CCI_REG8(0x30e8)
#define IMX335_AGAIN_MIN 0
-#define IMX335_AGAIN_MAX 240
+#define IMX335_AGAIN_MAX 100
#define IMX335_AGAIN_STEP 1
#define IMX335_AGAIN_DEFAULT 0
@@ -1179,6 +1179,14 @@ static int imx335_init_controls(struct imx335 *imx335)
IMX335_EXPOSURE_STEP,
IMX335_EXPOSURE_DEFAULT);
+ /*
+ * The sensor has an analog gain and a digital gain, both controlled
+ * through a single gain value, expressed in 0.3dB increments. Values
+ * from 0.0dB (0) to 30.0dB (100) apply analog gain only, higher values
+ * up to 72.0dB (240) add further digital gain. Limit the range to
+ * analog gain only, support for digital gain can be added separately
+ * if needed.
+ */
imx335->again_ctrl = v4l2_ctrl_new_std(ctrl_hdlr,
&imx335_ctrl_ops,
V4L2_CID_ANALOGUE_GAIN,