@@ -147,7 +147,7 @@ static u32 omap_bandgap_read_temp(struct omap_bandgap *bg_ptr, int id)
}
/* This is the Talert handler. Call it only if HAS(TALERT) is set */
-static irqreturn_t talert_irq_handler(int irq, void *data)
+static irqreturn_t omap_bandgap_talert_irq_handler(int irq, void *data)
{
struct omap_bandgap *bg_ptr = data;
struct temp_sensor_registers *tsr;
@@ -750,7 +750,7 @@ static int omap_bandgap_talert_init(struct omap_bandgap *bg_ptr,
return bg_ptr->irq;
}
ret = request_threaded_irq(bg_ptr->irq, NULL,
- talert_irq_handler,
+ omap_bandgap_talert_irq_handler,
IRQF_TRIGGER_HIGH | IRQF_ONESHOT,
"talert", bg_ptr);
if (ret) {
Simple rename to cope with file naming pattern. Signed-off-by: Eduardo Valentin <eduardo.valentin@ti.com> --- drivers/staging/omap-thermal/omap-bandgap.c | 4 ++-- 1 files changed, 2 insertions(+), 2 deletions(-)