diff mbox

[v2,6/8] thermal: ti-soc-thermal: Fetch slope and offset from DT

Message ID 1489046762-11288-7-git-send-email-j-keerthy@ti.com (mailing list archive)
State New, archived
Headers show

Commit Message

J, KEERTHY March 9, 2017, 8:06 a.m. UTC
Currently slope and offset values for calculating the hot spot
temperature of a thermal zone is being taken directly from driver
data. So fetch them from device tree.

Signed-off-by: Keerthy <j-keerthy@ti.com>
---
 drivers/thermal/ti-soc-thermal/ti-thermal-common.c | 4 ++--
 1 file changed, 2 insertions(+), 2 deletions(-)
diff mbox

Patch

diff --git a/drivers/thermal/ti-soc-thermal/ti-thermal-common.c b/drivers/thermal/ti-soc-thermal/ti-thermal-common.c
index 0586bd0..2054a5c 100644
--- a/drivers/thermal/ti-soc-thermal/ti-thermal-common.c
+++ b/drivers/thermal/ti-soc-thermal/ti-thermal-common.c
@@ -96,8 +96,8 @@  static inline int __ti_thermal_get_temp(void *devdata, int *temp)
 		return ret;
 
 	/* Default constants */
-	slope = s->slope;
-	constant = s->constant;
+	slope = thermal_zone_get_slope(data->ti_thermal);
+	constant = thermal_zone_get_offset(data->ti_thermal);
 
 	pcb_tz = data->pcb_tz;
 	/* In case pcb zone is available, use the extrapolation rule with it */