diff mbox series

[v2,3/5] clocksource: timer-ti-dm: Do not update counter on updating the period

Message ID 20200228095346.32177-4-lokeshvutla@ti.com (mailing list archive)
State New, archived
Headers show
Series clocksource: timer-ti-dm: Prepare for dynamic pwm period updates | expand

Commit Message

Lokesh Vutla Feb. 28, 2020, 9:53 a.m. UTC
Write to trigger register(OMAP_TIMER_TRIGGER_REG) will load the value
in Load register(OMAP_TIMER_LOAD_REG) into Counter register
(OMAP_TIMER_COUNTER_REG).

omap_dm_timer_set_load() writes into trigger register every time load
register is updated. When timer is configured in pwm mode, this causes
disruption in current pwm cycle, which is not expected especially when
pwm is used as PPS signal for synchronized PTP clocks. So do not write
into trigger register on updating the period.

Tested-by: Tony Lindgren <tony@atomide.com>
Signed-off-by: Lokesh Vutla <lokeshvutla@ti.com>
---
 drivers/clocksource/timer-ti-dm.c | 1 -
 1 file changed, 1 deletion(-)
diff mbox series

Patch

diff --git a/drivers/clocksource/timer-ti-dm.c b/drivers/clocksource/timer-ti-dm.c
index 9606103b92e0..4c32ee41339a 100644
--- a/drivers/clocksource/timer-ti-dm.c
+++ b/drivers/clocksource/timer-ti-dm.c
@@ -544,7 +544,6 @@  static int omap_dm_timer_set_load(struct omap_dm_timer *timer, int autoreload,
 	omap_dm_timer_write_reg(timer, OMAP_TIMER_CTRL_REG, l);
 	omap_dm_timer_write_reg(timer, OMAP_TIMER_LOAD_REG, load);
 
-	omap_dm_timer_write_reg(timer, OMAP_TIMER_TRIGGER_REG, 0);
 	omap_dm_timer_disable(timer);
 	return 0;
 }