@@ -2868,21 +2868,21 @@ MptDisplayIocCapabilities(MPT_ADAPTER *ioc)
printk(KERN_INFO "%s: ", ioc->name);
if (ioc->prod_name)
- printk("%s: ", ioc->prod_name);
- printk("Capabilities={");
+ pr_cont("%s: ", ioc->prod_name);
+ pr_cont("Capabilities={");
if (ioc->pfacts[0].ProtocolFlags & MPI_PORTFACTS_PROTOCOL_INITIATOR) {
- printk("Initiator");
+ pr_cont("Initiator");
i++;
}
if (ioc->pfacts[0].ProtocolFlags & MPI_PORTFACTS_PROTOCOL_TARGET) {
- printk("%sTarget", i ? "," : "");
+ pr_cont("%sTarget", i ? "," : "");
i++;
}
if (ioc->pfacts[0].ProtocolFlags & MPI_PORTFACTS_PROTOCOL_LAN) {
- printk("%sLAN", i ? "," : "");
+ pr_cont("%sLAN", i ? "," : "");
i++;
}
@@ -2891,12 +2891,12 @@ MptDisplayIocCapabilities(MPT_ADAPTER *ioc)
* This would probably evoke more questions than it's worth
*/
if (ioc->pfacts[0].ProtocolFlags & MPI_PORTFACTS_PROTOCOL_TARGET) {
- printk("%sLogBusAddr", i ? "," : "");
+ pr_cont("%sLogBusAddr", i ? "," : "");
i++;
}
#endif
- printk("}\n");
+ pr_cont("}\n");
}
/*=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=*/
Fix the printk continuations when running the mptfusion driver. This patch brings the capabilities into one single syslog line again: mptbase: ioc1: Initiating bringup ioc1: LSI53C1030 B2: Capabilities={Initiator,Target} scsi host3: ioc1: LSI53C1030 B2, FwRev=01032341h, Ports=1, MaxQ=255, IRQ=67 Tested on a parisc C8000 machine. Signed-off-by: Helge Deller <deller@gmx.de> -- To unsubscribe from this list: send the line "unsubscribe linux-parisc" in the body of a message to majordomo@vger.kernel.org More majordomo info at http://vger.kernel.org/majordomo-info.html