Kishon Vijay Abraham I Dec. 15, 2015, 9:16 a.m. UTC
No functional change. Previously omap_control_phy_power() was used to power
off the PHY during probe. But once PIPE3 driver is adapted to use syscon,
omap_control_phy_power() cannot be used. Hence used ti_pipe3_power_off
to power off the PHY.

Signed-off-by: Kishon Vijay Abraham I <kishon@ti.com>
Acked-by: Roger Quadros <rogerq@ti.com>
---
 drivers/phy/phy-ti-pipe3.c |    5 +++--
 1 file changed, 3 insertions(+), 2 deletions(-)
diff mbox

Patch

diff --git a/drivers/phy/phy-ti-pipe3.c b/drivers/phy/phy-ti-pipe3.c
index 1991efd..0ce4194 100644
--- a/drivers/phy/phy-ti-pipe3.c
+++ b/drivers/phy/phy-ti-pipe3.c
@@ -475,8 +475,6 @@  static int ti_pipe3_probe(struct platform_device *pdev)
 	if (ret)
 		return ret;
 
-	omap_control_phy_power(phy->control_dev, 0);
-
 	platform_set_drvdata(pdev, phy);
 	pm_runtime_enable(dev);
 
@@ -495,6 +493,9 @@  static int ti_pipe3_probe(struct platform_device *pdev)
 		return PTR_ERR(generic_phy);
 
 	phy_set_drvdata(generic_phy, phy);
+
+	ti_pipe3_power_off(generic_phy);
+
 	phy_provider = devm_of_phy_provider_register(dev, of_phy_simple_xlate);
 	if (IS_ERR(phy_provider))
 		return PTR_ERR(phy_provider);