diff mbox series

[12/27] ARM: dts: Configure simple-pm-bus for dra7 l4_per2

Message ID 20210126082716.54358-13-tony@atomide.com (mailing list archive)
State Not Applicable
Headers show
Series Update dra7 to probe with genpd to drop legacy pdata | expand

Commit Message

Tony Lindgren Jan. 26, 2021, 8:27 a.m. UTC
We can now probe interconnects with device tree only configuration using
simple-pm-bus and genpd.

Signed-off-by: Tony Lindgren <tony@atomide.com>
---
 arch/arm/boot/dts/dra7-l4.dtsi | 7 +++++--
 1 file changed, 5 insertions(+), 2 deletions(-)
diff mbox series

Patch

diff --git a/arch/arm/boot/dts/dra7-l4.dtsi b/arch/arm/boot/dts/dra7-l4.dtsi
--- a/arch/arm/boot/dts/dra7-l4.dtsi
+++ b/arch/arm/boot/dts/dra7-l4.dtsi
@@ -2302,7 +2302,10 @@  segment@200000 {					/* 0x48200000 */
 };
 
 &l4_per2 {						/* 0x48400000 */
-	compatible = "ti,dra7-l4-per2", "simple-bus";
+	compatible = "ti,dra7-l4-per2", "simple-pm-bus";
+	power-domains = <&prm_l4per>;
+	clocks = <&l4per2_clkctrl DRA7_L4PER2_L4_PER2_CLKCTRL 0>;
+	clock-names = "fck";
 	reg = <0x48400000 0x800>,
 	      <0x48400800 0x800>,
 	      <0x48401000 0x400>,
@@ -2322,7 +2325,7 @@  &l4_per2 {						/* 0x48400000 */
 		 <0x48454000 0x48454000 0x400000>;	/* L3 data port */
 
 	segment@0 {					/* 0x48400000 */
-		compatible = "simple-bus";
+		compatible = "simple-pm-bus";
 		#address-cells = <1>;
 		#size-cells = <1>;
 		ranges = <0x00000000 0x00000000 0x000800>,	/* ap 0 */