@@ -907,6 +907,54 @@ static void chromeos_fixup_apl_pci_l1ss_capability(struct pci_dev *dev)
DECLARE_PCI_FIXUP_FINAL(PCI_VENDOR_ID_INTEL, 0x5ad6, chromeos_save_apl_pci_l1ss_capability);
DECLARE_PCI_FIXUP_RESUME(PCI_VENDOR_ID_INTEL, 0x5ad6, chromeos_fixup_apl_pci_l1ss_capability);
+/*
+ * Disable D3cold on Asus B1400 NVMe-NCIe bridge
+ *
+ * On this platform with VMD off, the NVMe device cannot successfully power
+ * back on from D3cold. This appears to be an untested transition by the
+ * vendor: Windows leaves the NVMe and parent bridge in D0 during suspend.
+ *
+ * We disable D3cold on the parent bridge for simplicity, and the fact that
+ * both parent bridge and NVMe device share the same power resource.
+ *
+ * This is only needed on BIOS versions before 308; the newer versions flip
+ * StorageD3Enable from 1 to 0.
+ */
+static const struct dmi_system_id asus_nvme_broken_d3cold_table[] = {
+ {
+ .matches = {
+ DMI_MATCH(DMI_SYS_VENDOR, "ASUSTeK COMPUTER INC."),
+ DMI_MATCH(DMI_BIOS_VERSION, "B1400CEAE.304"),
+ },
+ },
+ {
+ .matches = {
+ DMI_MATCH(DMI_SYS_VENDOR, "ASUSTeK COMPUTER INC."),
+ DMI_MATCH(DMI_BIOS_VERSION, "B1400CEAE.305"),
+ },
+ },
+ {
+ .matches = {
+ DMI_MATCH(DMI_SYS_VENDOR, "ASUSTeK COMPUTER INC."),
+ DMI_MATCH(DMI_BIOS_VERSION, "B1400CEAE.306"),
+ },
+ },
+ {
+ .matches = {
+ DMI_MATCH(DMI_SYS_VENDOR, "ASUSTeK COMPUTER INC."),
+ DMI_MATCH(DMI_BIOS_VERSION, "B1400CEAE.307"),
+ },
+ },
+ {}
+};
+
+static void asus_disable_nvme_d3cold(struct pci_dev *pdev)
+{
+ if (dmi_check_system(asus_nvme_broken_d3cold_table) > 0)
+ pci_d3cold_disable(pdev);
+}
+DECLARE_PCI_FIXUP_FINAL(PCI_VENDOR_ID_INTEL, 0x9a09, asus_disable_nvme_d3cold);
+
#ifdef CONFIG_SUSPEND
/*