Message ID | 20240327133013.3982199-1-niklas.soderlund+renesas@ragnatech.se (mailing list archive) |
---|---|
Headers | show |
Series | thermal: rcar_gen3: Use temperature approximation from datasheet | expand |
On 27/03/2024 14:30, Niklas Söderlund wrote: > Hello, > > When the driver was first added the temperature approximation was > reversed engineered from an out-of-tree driver as the datasheets of the > time did not contain this information. Recent datasheets, both Gen3 and > Gen4, now contains this information. > > This series changes the temperature approximation formula to match > what's described in the datasheets. It has been tested on both Gen3 and > Gen4 with minimal changes in temperatures reported. > > Patch 1 is a cleanup making the scope of a constant more clear. Patch > 2 is the real work changing the approximation formula. > > Compared to v1 patch 3/3 have been squashed intro v2 patch 2/2. This is > due to a suggestion from Geert where the precision in approximation > could be increased while removing the need for the changed done in v1 > 3/3, thanks Geert! > > See individual patches for detailed changelog. Applied, thanks