@@ -55,6 +55,8 @@ The \fB-l --log\fP option write data to /var/tmp/tmon.log
.PP
The \fB-t --time-interval\fP option sets the polling interval in seconds
.PP
+The \fB-T --target-temp\fP option sets the initial target temperature
+.PP
The \fB-v --version\fP option shows the version of \fBtmon \fP
.PP
The \fB-z --zone\fP option sets the target therma zone instance to be controlled
@@ -64,6 +64,7 @@ void usage()
printf(" -h, --help show this help message\n");
printf(" -l, --log log data to /var/tmp/tmon.log\n");
printf(" -t, --time-interval sampling time interval, > 1 sec.\n");
+ printf(" -T, --target-temp initial target temperature\n");
printf(" -v, --version show version\n");
printf(" -z, --zone target thermal zone id\n");
@@ -219,6 +220,7 @@ static struct option opts[] = {
{ "control", 1, NULL, 'c' },
{ "daemon", 0, NULL, 'd' },
{ "time-interval", 1, NULL, 't' },
+ { "target-temp", 1, NULL, 'T' },
{ "log", 0, NULL, 'l' },
{ "help", 0, NULL, 'h' },
{ "version", 0, NULL, 'v' },
@@ -231,7 +233,7 @@ int main(int argc, char **argv)
{
int err = 0;
int id2 = 0, c;
- double yk = 0.0; /* controller output */
+ double yk = 0.0, temp; /* controller output */
int target_tz_index;
if (geteuid() != 0) {
@@ -239,7 +241,7 @@ int main(int argc, char **argv)
exit(EXIT_FAILURE);
}
- while ((c = getopt_long(argc, argv, "c:dlht:vgz:", opts, &id2)) != -1) {
+ while ((c = getopt_long(argc, argv, "c:dlht:T:vgz:", opts, &id2)) != -1) {
switch (c) {
case 'c':
no_control = 0;
@@ -254,6 +256,14 @@ int main(int argc, char **argv)
if (ticktime < 1)
ticktime = 1;
break;
+ case 'T':
+ temp = strtod(optarg, NULL);
+ if (temp < 0) {
+ fprintf(stderr, "error: temperature must be positive\n");
+ return 1;
+ }
+ target_temp_user = temp;
+ break;
case 'l':
printf("Logging data to /var/tmp/tmon.log\n");
logging = 1;
If we launch in daemon mode (--daemon), we don't have the ncurses UI, but we might want to set the target temperature still. For example, someone might stick the following in their boot script: tmon --control intel_powerclamp --target-temp 90 --log --daemon This would turn on CPU idle injection when we're around 90 degrees celsius, and would log temperature and throttling info to /var/tmp/tmon.log. Signed-off-by: Brian Norris <computersforpeace@gmail.com> --- tools/thermal/tmon/tmon.8 | 2 ++ tools/thermal/tmon/tmon.c | 14 ++++++++++++-- 2 files changed, 14 insertions(+), 2 deletions(-)