@@ -3,10 +3,35 @@ Bindings for a fan connected to the PWM lines
Required properties:
- compatible : "pwm-fan"
- pwms : the PWM that is used to control the PWM fan
+- cooling-levels : PWM duty cycle values in a range from 0 to 255
+ which correspond to thermal cooling states
Example:
- pwm-fan {
+ fan0: pwm-fan {
compatible = "pwm-fan";
- status = "okay";
+ cooling-min-state = <0>;
+ cooling-max-state = <3>;
+ #cooling-cells = <2>;
pwms = <&pwm 0 10000 0>;
+ cooling-levels = <0 102 170 230>;
};
+
+ thermal-zones {
+ cpu_thermal: cpu-thermal {
+ thermal-sensors = <&tmu 0>;
+ polling-delay-passive = <0>;
+ polling-delay = <0>;
+ trips {
+ cpu_alert1: cpu-alert1 {
+ temperature = <100000>; /* millicelsius */
+ hysteresis = <2000>; /* millicelsius */
+ type = "passive";
+ };
+ };
+ cooling-maps {
+ map0 {
+ trip = <&cpu_alert1>;
+ cooling-device = <&fan0 0 1>;
+ };
+ };
+ };