On Thu, Apr 26, 2018 at 01:51:22PM +0200, Bartlomiej Zolnierkiewicz wrote: > On Exynos4210 one-point trimming is always used and data->temp_error1 > is equal to 75. Therefore temp_to_code() will never return negative > value for the reference temperature conversion. > > There should be no functional changes caused by this patch. > > Signed-off-by: Bartlomiej Zolnierkiewicz <b.zolnierkie@samsung.com> > --- > drivers/thermal/samsung/exynos_tmu.c | 6 +----- Reviewed-by: Daniel Lezcano <daniel.lezcano@linaro.org>
diff --git a/drivers/thermal/samsung/exynos_tmu.c b/drivers/thermal/samsung/exynos_tmu.c index 58cd68e..26a0cb9 100644 --- a/drivers/thermal/samsung/exynos_tmu.c +++ b/drivers/thermal/samsung/exynos_tmu.c @@ -423,10 +423,6 @@ static int exynos4210_tmu_initialize(struct platform_device *pdev) /* Write temperature code for threshold */ reference = trips[0].temperature / MCELSIUS; threshold_code = temp_to_code(data, reference); - if (threshold_code < 0) { - ret = threshold_code; - goto out; - } writeb(threshold_code, data->base + EXYNOS4210_TMU_REG_THRESHOLD_TEMP); for (i = 0; i < of_thermal_get_ntrips(tz); i++) { @@ -436,7 +432,7 @@ static int exynos4210_tmu_initialize(struct platform_device *pdev) } data->tmu_clear_irqs(data); -out: + return ret; }
On Exynos4210 one-point trimming is always used and data->temp_error1 is equal to 75. Therefore temp_to_code() will never return negative value for the reference temperature conversion. There should be no functional changes caused by this patch. Signed-off-by: Bartlomiej Zolnierkiewicz <b.zolnierkie@samsung.com> --- drivers/thermal/samsung/exynos_tmu.c | 6 +----- 1 file changed, 1 insertion(+), 5 deletions(-)