diff mbox series

thermal: imx: Do NOT return -EPROBE_DEFER when "#cooling-cells" is present

Message ID 1603340694-29826-1-git-send-email-Anson.Huang@nxp.com (mailing list archive)
State New, archived
Delegated to: Daniel Lezcano
Headers show
Series thermal: imx: Do NOT return -EPROBE_DEFER when "#cooling-cells" is present | expand

Commit Message

Anson Huang Oct. 22, 2020, 4:24 a.m. UTC
The legacy CPU cooling should ONLY be used when "#cooling-cells" is NOT
present in cpu node, current implementation for registering legacy cooling
always return -EPROBE_DEFER when cpufreq is NOT ready, that will cause
thermal driver probe failed when cpufreq failed to probe with a non
-EPROBE_DEFER reason. In such case, thermal driver should continue probe
and provide temperature monitor and other cooling methods.

So, for the case of "#cooling-cells" present in cpu node, no need to
return -EPROBE_DEFER even cpufreq is NOT ready, this is to make sure
thermal driver can continue probe.

Signed-off-by: Anson Huang <Anson.Huang@nxp.com>
---
 drivers/thermal/imx_thermal.c | 25 +++++++++++++++++++------
 1 file changed, 19 insertions(+), 6 deletions(-)
diff mbox series

Patch

diff --git a/drivers/thermal/imx_thermal.c b/drivers/thermal/imx_thermal.c
index 9f00182..df60dcb 100644
--- a/drivers/thermal/imx_thermal.c
+++ b/drivers/thermal/imx_thermal.c
@@ -630,17 +630,29 @@  MODULE_DEVICE_TABLE(of, of_imx_thermal_match);
 static int imx_thermal_register_legacy_cooling(struct imx_thermal_data *data)
 {
 	struct device_node *np;
+	struct device *cpu_dev;
 	int ret = 0;
 
-	data->policy = cpufreq_cpu_get(0);
-	if (!data->policy) {
-		pr_debug("%s: CPUFreq policy not found\n", __func__);
-		return -EPROBE_DEFER;
+	cpu_dev = get_cpu_device(0);
+	if (!cpu_dev) {
+		pr_err("imx thermal: failed to get cpu0 device\n");
+		return -ENODEV;
+	}
+
+	np = of_node_get(cpu_dev->of_node);
+	if (!np) {
+		pr_err("imx thermal: failed to find cpu0 node\n");
+		return -ENOENT;
 	}
 
-	np = of_get_cpu_node(data->policy->cpu, NULL);
+	if (!of_find_property(np, "#cooling-cells", NULL)) {
+		data->policy = cpufreq_cpu_get(0);
+		if (!data->policy) {
+			pr_debug("%s: CPUFreq policy not found\n", __func__);
+			ret = -EPROBE_DEFER;
+			goto put_node;
+		}
 
-	if (!np || !of_find_property(np, "#cooling-cells", NULL)) {
 		data->cdev = cpufreq_cooling_register(data->policy);
 		if (IS_ERR(data->cdev)) {
 			ret = PTR_ERR(data->cdev);
@@ -648,6 +660,7 @@  static int imx_thermal_register_legacy_cooling(struct imx_thermal_data *data)
 		}
 	}
 
+put_node:
 	of_node_put(np);
 
 	return ret;