On Tue, Mar 10, 2020 at 6:02 PM Niklas Söderlund <niklas.soderlund+renesas@ragnatech.se> wrote: > With the ctemp value returned instead of cached in the private data > structure their is no need to take the lock when translating ctemp into > a temperature. > > Signed-off-by: Niklas Söderlund <niklas.soderlund+renesas@ragnatech.se> Reviewed-by: Geert Uytterhoeven <geert+renesas@glider.be> Gr{oetje,eeting}s, Geert
diff --git a/drivers/thermal/rcar_thermal.c b/drivers/thermal/rcar_thermal.c index 953dc28d1dd1d499..8bdcb449bd280a18 100644 --- a/drivers/thermal/rcar_thermal.c +++ b/drivers/thermal/rcar_thermal.c @@ -254,24 +254,20 @@ static int rcar_thermal_update_temp(struct rcar_thermal_priv *priv) static int rcar_thermal_get_current_temp(struct rcar_thermal_priv *priv, int *temp) { - int ctemp, tmp; + int ctemp; ctemp = rcar_thermal_update_temp(priv); if (ctemp < 0) return ctemp; - mutex_lock(&priv->lock); + /* Guaranteed operating range is -45C to 125C. */ + if (priv->chip->ctemp_bands == 1) - tmp = MCELSIUS((ctemp * 5) - 65); + *temp = MCELSIUS((ctemp * 5) - 65); else if (ctemp < 24) - tmp = MCELSIUS(((ctemp * 55) - 720) / 10); + *temp = MCELSIUS(((ctemp * 55) - 720) / 10); else - tmp = MCELSIUS((ctemp * 5) - 60); - mutex_unlock(&priv->lock); - - /* Guaranteed operating range is -45C to 125C. */ - - *temp = tmp; + *temp = MCELSIUS((ctemp * 5) - 60); return 0; }
With the ctemp value returned instead of cached in the private data structure their is no need to take the lock when translating ctemp into a temperature. Signed-off-by: Niklas Söderlund <niklas.soderlund+renesas@ragnatech.se> --- drivers/thermal/rcar_thermal.c | 16 ++++++---------- 1 file changed, 6 insertions(+), 10 deletions(-)