Message ID | 20200424082340.4127-1-michael.kao@mediatek.com (mailing list archive) |
---|---|
State | Not Applicable, archived |
Headers | show |
Series | [RESEND] arm64: dts: mt8173: fix cooling device range | expand |
On 24/04/2020 10:23, Michael Kao wrote: > When thermal reaches target temperature,it would be pinned to state 0 > (max frequency and power). > Fix the throttling range to no limit. > > Signed-off-by: Hsin-Yi Wang <hsinyi@chromium.org> > Signed-off-by: Michael Kao <michael.kao@mediatek.com> applied to v5.7-next/dts64 Thanks! > --- > arch/arm64/boot/dts/mediatek/mt8173.dtsi | 13 +++++++++---- > 1 file changed, 9 insertions(+), 4 deletions(-) > > diff --git a/arch/arm64/boot/dts/mediatek/mt8173.dtsi b/arch/arm64/boot/dts/mediatek/mt8173.dtsi > index ccb8e88a60c5..cae2cec46cdc 100644 > --- a/arch/arm64/boot/dts/mediatek/mt8173.dtsi > +++ b/arch/arm64/boot/dts/mediatek/mt8173.dtsi > @@ -19,6 +19,7 @@ > #include <dt-bindings/power/mt8173-power.h> > #include <dt-bindings/reset/mt8173-resets.h> > #include <dt-bindings/gce/mt8173-gce.h> > +#include <dt-bindings/thermal/thermal.h> > #include "mt8173-pinfunc.h" > > / { > @@ -294,14 +295,18 @@ > cooling-maps { > map@0 { > trip = <&target>; > - cooling-device = <&cpu0 0 0>, > - <&cpu1 0 0>; > + cooling-device = <&cpu0 THERMAL_NO_LIMIT > + THERMAL_NO_LIMIT>, > + <&cpu1 THERMAL_NO_LIMIT > + THERMAL_NO_LIMIT>; > contribution = <3072>; > }; > map@1 { > trip = <&target>; > - cooling-device = <&cpu2 0 0>, > - <&cpu3 0 0>; > + cooling-device = <&cpu2 THERMAL_NO_LIMIT > + THERMAL_NO_LIMIT>, > + <&cpu3 THERMAL_NO_LIMIT > + THERMAL_NO_LIMIT>; > contribution = <1024>; > }; > }; >
diff --git a/arch/arm64/boot/dts/mediatek/mt8173.dtsi b/arch/arm64/boot/dts/mediatek/mt8173.dtsi index ccb8e88a60c5..cae2cec46cdc 100644 --- a/arch/arm64/boot/dts/mediatek/mt8173.dtsi +++ b/arch/arm64/boot/dts/mediatek/mt8173.dtsi @@ -19,6 +19,7 @@ #include <dt-bindings/power/mt8173-power.h> #include <dt-bindings/reset/mt8173-resets.h> #include <dt-bindings/gce/mt8173-gce.h> +#include <dt-bindings/thermal/thermal.h> #include "mt8173-pinfunc.h" / { @@ -294,14 +295,18 @@ cooling-maps { map@0 { trip = <&target>; - cooling-device = <&cpu0 0 0>, - <&cpu1 0 0>; + cooling-device = <&cpu0 THERMAL_NO_LIMIT + THERMAL_NO_LIMIT>, + <&cpu1 THERMAL_NO_LIMIT + THERMAL_NO_LIMIT>; contribution = <3072>; }; map@1 { trip = <&target>; - cooling-device = <&cpu2 0 0>, - <&cpu3 0 0>; + cooling-device = <&cpu2 THERMAL_NO_LIMIT + THERMAL_NO_LIMIT>, + <&cpu3 THERMAL_NO_LIMIT + THERMAL_NO_LIMIT>; contribution = <1024>; }; };