@@ -11,6 +11,7 @@
#include <linux/regmap.h>
#include <linux/sizes.h>
#include <linux/thermal.h>
+#include <linux/units.h>
#include "thermal_core.h"
#include "thermal_hwmon.h"
@@ -23,6 +24,7 @@
#define TMTMIR_DEFAULT 0x0000000f
#define TIER_DISABLE 0x0
#define TEUMR0_V2 0x51009c00
+#define TMSARA_V2 0xe
#define TMU_VER1 0x1
#define TMU_VER2 0x2
@@ -50,6 +52,9 @@
* Site Register
*/
#define TRITSR_V BIT(31)
+#define REGS_V2_TMSAR(n) (0x304 + 16 * (n)) /* TMU monitoring
+ * site adjustment register
+ */
#define REGS_TTRnCR(n) (0xf10 + 4 * (n)) /* Temperature Range n
* Control Register
*/
@@ -100,7 +105,11 @@ static int tmu_get_temp(void *p, int *temp)
10 * USEC_PER_MSEC))
return -ENODATA;
- *temp = (val & 0xff) * 1000;
+ /* For TMUv2, temperature reading in degrees Kelvin */
+ if (qdata->ver == TMU_VER1)
+ *temp = (val & 0xff) * 1000;
+ else
+ *temp = kelvin_to_millicelsius(val & 0x1ff);
return 0;
}
@@ -192,6 +201,8 @@ static int qoriq_tmu_calibration(struct device *dev,
static void qoriq_tmu_init_device(struct qoriq_tmu_data *data)
{
+ int i;
+
/* Disable interrupt, using polling instead */
regmap_write(data->regmap, REGS_TIER, TIER_DISABLE);
@@ -202,6 +213,8 @@ static void qoriq_tmu_init_device(struct qoriq_tmu_data *data)
} else {
regmap_write(data->regmap, REGS_V2_TMTMIR, TMTMIR_DEFAULT);
regmap_write(data->regmap, REGS_V2_TEUMR(0), TEUMR0_V2);
+ for (i = 0; i < 7; i++)
+ regmap_write(data->regmap, REGS_V2_TMSAR(i), TMSARA_V2);
}
/* Disable monitoring */
@@ -212,6 +225,7 @@ static const struct regmap_range qoriq_yes_ranges[] = {
regmap_reg_range(REGS_TMR, REGS_TSCFGR),
regmap_reg_range(REGS_TTRnCR(0), REGS_TTRnCR(3)),
regmap_reg_range(REGS_V2_TEUMR(0), REGS_V2_TEUMR(2)),
+ regmap_reg_range(REGS_V2_TMSAR(0), REGS_V2_TMSAR(15)),
regmap_reg_range(REGS_IPBRR(0), REGS_IPBRR(1)),
/* Read only registers below */
regmap_reg_range(REGS_TRITSR(0), REGS_TRITSR(15)),
For TMU v2, TMSAR registers need to be set properly to get the accurate temperature values. Also the temperature read needs to be converted to degree Celsius since it is in degrees Kelvin. Signed-off-by: Yuantian Tang <andy.tang@nxp.com> --- v3: - use kelvin_to_millicelsius() to convert the degree Kelvin drivers/thermal/qoriq_thermal.c | 16 +++++++++++++++- 1 file changed, 15 insertions(+), 1 deletion(-)