Daniel Lezcano March 10, 2021, 11:45 a.m. UTC
Currently the naming of a cooling device is just a cooling technique
followed by a number. When there are multiple cooling devices using
the same technique, it is impossible to clearly identify the related
device as this one is just a number.

For instance:

 thermal-cpufreq-0
 thermal-cpufreq-1
 etc ...

The 'thermal' prefix is redundant with the subsystem namespace. This
patch removes the 'thermal prefix and changes the number by the device
name. So the naming above becomes:

 cpufreq-cpu0
 cpufreq-cpu4
 etc ...

Signed-off-by: Daniel Lezcano <daniel.lezcano@linaro.org>
---
 drivers/thermal/cpufreq_cooling.c | 28 +++++++---------------------
 1 file changed, 7 insertions(+), 21 deletions(-)

Comments

Viresh Kumar March 12, 2021, 5:10 a.m. UTC | #1
On 10-03-21, 12:45, Daniel Lezcano wrote:
> Currently the naming of a cooling device is just a cooling technique
> followed by a number. When there are multiple cooling devices using
> the same technique, it is impossible to clearly identify the related
> device as this one is just a number.
> 
> For instance:
> 
>  thermal-cpufreq-0
>  thermal-cpufreq-1
>  etc ...
> 
> The 'thermal' prefix is redundant with the subsystem namespace. This
> patch removes the 'thermal prefix and changes the number by the device
> name. So the naming above becomes:
> 
>  cpufreq-cpu0
>  cpufreq-cpu4
>  etc ...
> 
> Signed-off-by: Daniel Lezcano <daniel.lezcano@linaro.org>
> ---
>  drivers/thermal/cpufreq_cooling.c | 28 +++++++---------------------
>  1 file changed, 7 insertions(+), 21 deletions(-)

For 1,3/3

Acked-by: Viresh Kumar <viresh.kumar@linaro.org>
Lukasz Luba March 12, 2021, 10:58 a.m. UTC | #2
Hi Daniel,

Only minor comments.

On 3/10/21 11:45 AM, Daniel Lezcano wrote:
> Currently the naming of a cooling device is just a cooling technique
> followed by a number. When there are multiple cooling devices using
> the same technique, it is impossible to clearly identify the related
> device as this one is just a number.
> 
> For instance:
> 
>   thermal-cpufreq-0
>   thermal-cpufreq-1
>   etc ...
> 
> The 'thermal' prefix is redundant with the subsystem namespace. This
> patch removes the 'thermal prefix and changes the number by the device

missing ', after 'thermal

> name. So the naming above becomes:
> 
>   cpufreq-cpu0
>   cpufreq-cpu4
>   etc ...
> 
> Signed-off-by: Daniel Lezcano <daniel.lezcano@linaro.org>
> ---
>   drivers/thermal/cpufreq_cooling.c | 28 +++++++---------------------
>   1 file changed, 7 insertions(+), 21 deletions(-)
> 
> diff --git a/drivers/thermal/cpufreq_cooling.c b/drivers/thermal/cpufreq_cooling.c
> index 10af3341e5ea..cf0332bbdcd3 100644
> --- a/drivers/thermal/cpufreq_cooling.c
> +++ b/drivers/thermal/cpufreq_cooling.c
> @@ -13,6 +13,7 @@
>   #include <linux/cpu.h>
>   #include <linux/cpufreq.h>
>   #include <linux/cpu_cooling.h>
> +#include <linux/device.h>
>   #include <linux/energy_model.h>
>   #include <linux/err.h>
>   #include <linux/export.h>

You can now also remove the header:
#include <linux/idr.h>


other than that, LGTM

Reviewed-by: Lukasz Luba <lukasz.luba@arm.com>
diff mbox series

Patch

diff --git a/drivers/thermal/cpufreq_cooling.c b/drivers/thermal/cpufreq_cooling.c
index 10af3341e5ea..cf0332bbdcd3 100644
--- a/drivers/thermal/cpufreq_cooling.c
+++ b/drivers/thermal/cpufreq_cooling.c
@@ -13,6 +13,7 @@ 
 #include <linux/cpu.h>
 #include <linux/cpufreq.h>
 #include <linux/cpu_cooling.h>
+#include <linux/device.h>
 #include <linux/energy_model.h>
 #include <linux/err.h>
 #include <linux/export.h>
@@ -50,8 +51,6 @@  struct time_in_idle {
 
 /**
  * struct cpufreq_cooling_device - data for cooling device with cpufreq
- * @id: unique integer value corresponding to each cpufreq_cooling_device
- *	registered.
  * @last_load: load measured by the latest call to cpufreq_get_requested_power()
  * @cpufreq_state: integer value representing the current state of cpufreq
  *	cooling	devices.
@@ -69,7 +68,6 @@  struct time_in_idle {
  * cpufreq_cooling_device.
  */
 struct cpufreq_cooling_device {
-	int id;
 	u32 last_load;
 	unsigned int cpufreq_state;
 	unsigned int max_level;
@@ -82,7 +80,6 @@  struct cpufreq_cooling_device {
 	struct freq_qos_request qos_req;
 };
 
-static DEFINE_IDA(cpufreq_ida);
 static DEFINE_MUTEX(cooling_list_lock);
 static LIST_HEAD(cpufreq_cdev_list);
 
@@ -528,11 +525,11 @@  __cpufreq_cooling_register(struct device_node *np,
 {
 	struct thermal_cooling_device *cdev;
 	struct cpufreq_cooling_device *cpufreq_cdev;
-	char dev_name[THERMAL_NAME_LENGTH];
 	unsigned int i;
 	struct device *dev;
 	int ret;
 	struct thermal_cooling_device_ops *cooling_ops;
+	char name[THERMAL_NAME_LENGTH];
 
 	dev = get_cpu_device(policy->cpu);
 	if (unlikely(!dev)) {
@@ -567,16 +564,6 @@  __cpufreq_cooling_register(struct device_node *np,
 	/* max_level is an index, not a counter */
 	cpufreq_cdev->max_level = i - 1;
 
-	ret = ida_simple_get(&cpufreq_ida, 0, 0, GFP_KERNEL);
-	if (ret < 0) {
-		cdev = ERR_PTR(ret);
-		goto free_idle_time;
-	}
-	cpufreq_cdev->id = ret;
-
-	snprintf(dev_name, sizeof(dev_name), "thermal-cpufreq-%d",
-		 cpufreq_cdev->id);
-
 	cooling_ops = &cpufreq_cooling_ops;
 
 #ifdef CONFIG_THERMAL_GOV_POWER_ALLOCATOR
@@ -591,7 +578,7 @@  __cpufreq_cooling_register(struct device_node *np,
 		pr_err("%s: unsorted frequency tables are not supported\n",
 		       __func__);
 		cdev = ERR_PTR(-EINVAL);
-		goto remove_ida;
+		goto free_idle_time;
 	}
 
 	ret = freq_qos_add_request(&policy->constraints,
@@ -601,10 +588,12 @@  __cpufreq_cooling_register(struct device_node *np,
 		pr_err("%s: Failed to add freq constraint (%d)\n", __func__,
 		       ret);
 		cdev = ERR_PTR(ret);
-		goto remove_ida;
+		goto free_idle_time;
 	}
 
-	cdev = thermal_of_cooling_device_register(np, dev_name, cpufreq_cdev,
+	snprintf(name, sizeof(name), "cpufreq-%s", dev_name(dev));
+
+	cdev = thermal_of_cooling_device_register(np, name, cpufreq_cdev,
 						  cooling_ops);
 	if (IS_ERR(cdev))
 		goto remove_qos_req;
@@ -617,8 +606,6 @@  __cpufreq_cooling_register(struct device_node *np,
 
 remove_qos_req:
 	freq_qos_remove_request(&cpufreq_cdev->qos_req);
-remove_ida:
-	ida_simple_remove(&cpufreq_ida, cpufreq_cdev->id);
 free_idle_time:
 	free_idle_time(cpufreq_cdev);
 free_cdev:
@@ -712,7 +699,6 @@  void cpufreq_cooling_unregister(struct thermal_cooling_device *cdev)
 
 	thermal_cooling_device_unregister(cdev);
 	freq_qos_remove_request(&cpufreq_cdev->qos_req);
-	ida_simple_remove(&cpufreq_ida, cpufreq_cdev->id);
 	free_idle_time(cpufreq_cdev);
 	kfree(cpufreq_cdev);
 }