diff mbox series

thermal/drivers/rzg2l: Fix comments

Message ID 20220718121440.556408-1-biju.das.jz@bp.renesas.com (mailing list archive)
State New, archived
Delegated to: Daniel Lezcano
Headers show
Series thermal/drivers/rzg2l: Fix comments | expand

Commit Message

Biju Das July 18, 2022, 12:14 p.m. UTC
This patch replaces 'Capture times'->'Total number of ADC data samples' as
the former does not really explain much.

It also fixes the typo
 * caliberation->calibration

Lastly, as per the coding style /* should be on a separate line.
This patch fixes this issue.

Reported-by: Pavel Machek <pavel@denx.de>
Signed-off-by: Biju Das <biju.das.jz@bp.renesas.com>
---
 drivers/thermal/rzg2l_thermal.c | 18 +++++++++++-------
 1 file changed, 11 insertions(+), 7 deletions(-)

Comments

Daniel Lezcano July 18, 2022, 1:41 p.m. UTC | #1
On 18/07/2022 14:14, Biju Das wrote:
> This patch replaces 'Capture times'->'Total number of ADC data samples' as
> the former does not really explain much.
> 
> It also fixes the typo
>   * caliberation->calibration
> 
> Lastly, as per the coding style /* should be on a separate line.
> This patch fixes this issue.
> 
> Reported-by: Pavel Machek <pavel@denx.de>
> Signed-off-by: Biju Das <biju.das.jz@bp.renesas.com>
> ---

Applied, thanks
diff mbox series

Patch

diff --git a/drivers/thermal/rzg2l_thermal.c b/drivers/thermal/rzg2l_thermal.c
index be07e04c6926..51ae80eda6af 100644
--- a/drivers/thermal/rzg2l_thermal.c
+++ b/drivers/thermal/rzg2l_thermal.c
@@ -47,7 +47,7 @@ 
 
 #define TS_CODE_AVE_SCALE(x)	((x) * 1000000)
 #define MCELSIUS(temp)		((temp) * MILLIDEGREE_PER_DEGREE)
-#define TS_CODE_CAP_TIMES	8	/* Capture  times */
+#define TS_CODE_CAP_TIMES	8	/* Total number of ADC data samples */
 
 #define RZG2L_THERMAL_GRAN	500	/* milli Celsius */
 #define RZG2L_TSU_SS_TIMEOUT_US	1000
@@ -80,7 +80,8 @@  static int rzg2l_thermal_get_temp(void *devdata, int *temp)
 	int val, i;
 
 	for (i = 0; i < TS_CODE_CAP_TIMES ; i++) {
-		/* TSU repeats measurement at 20 microseconds intervals and
+		/*
+		 * TSU repeats measurement at 20 microseconds intervals and
 		 * automatically updates the results of measurement. As per
 		 * the HW manual for measuring temperature we need to read 8
 		 * values consecutively and then take the average.
@@ -92,16 +93,18 @@  static int rzg2l_thermal_get_temp(void *devdata, int *temp)
 
 	ts_code_ave = result / TS_CODE_CAP_TIMES;
 
-	/* Calculate actual sensor value by applying curvature correction formula
+	/*
+	 * Calculate actual sensor value by applying curvature correction formula
 	 * dsensor = ts_code_ave / (1 + ts_code_ave * 0.000013). Here we are doing
 	 * integer calculation by scaling all the values by 1000000.
 	 */
 	dsensor = TS_CODE_AVE_SCALE(ts_code_ave) /
 		(TS_CODE_AVE_SCALE(1) + (ts_code_ave * CURVATURE_CORRECTION_CONST));
 
-	/* The temperature Tj is calculated by the formula
+	/*
+	 * The temperature Tj is calculated by the formula
 	 * Tj = (dsensor − calib1) * 165/ (calib0 − calib1) − 40
-	 * where calib0 and calib1 are the caliberation values.
+	 * where calib0 and calib1 are the calibration values.
 	 */
 	val = ((dsensor - priv->calib1) * (MCELSIUS(165) /
 		(priv->calib0 - priv->calib1))) - MCELSIUS(40);
@@ -122,7 +125,8 @@  static int rzg2l_thermal_init(struct rzg2l_thermal_priv *priv)
 	rzg2l_thermal_write(priv, TSU_SM, TSU_SM_NORMAL_MODE);
 	rzg2l_thermal_write(priv, TSU_ST, 0);
 
-	/* Before setting the START bit, TSU should be in normal operating
+	/*
+	 * Before setting the START bit, TSU should be in normal operating
 	 * mode. As per the HW manual, it will take 60 µs to place the TSU
 	 * into normal operating mode.
 	 */
@@ -217,7 +221,7 @@  static int rzg2l_thermal_probe(struct platform_device *pdev)
 	if (ret)
 		goto err;
 
-	dev_dbg(dev, "TSU probed with %s caliberation values",
+	dev_dbg(dev, "TSU probed with %s calibration values",
 		rzg2l_thermal_read(priv, OTPTSUTRIM_REG(0)) ?  "hw" : "sw");
 
 	return 0;