@@ -75,6 +75,22 @@ patternProperties:
framework and assumes that the thermal sensors in this zone
support interrupts.
+ critical-action:
+ $ref: /schemas/types.yaml#/definitions/string
+ description: |
+ The action the OS should perform after the critical temperature is reached.
+ By default the system will shutdown as a safe action to prevent damage
+ to the hardware, if the property is not set.
+ The shutdown action should be always the default and preferred one.
+ Choose 'reboot' with care, as the hardware may be in thermal stress,
+ thus leading to infinite reboots that may cause damage to the hardware.
+ Make sure the firmware/bootloader will act as the last resort and take
+ over the thermal control.
+
+ enum:
+ - shutdown
+ - reboot
+
thermal-sensors:
$ref: /schemas/types.yaml#/definitions/phandle-array