From patchwork Tue Apr 16 12:18:18 2024 Content-Type: text/plain; charset="utf-8" MIME-Version: 1.0 Content-Transfer-Encoding: 8bit X-Patchwork-Submitter: Mike Looijmans X-Patchwork-Id: 13631761 Received: from EUR01-DB5-obe.outbound.protection.outlook.com (mail-db5eur01on2112.outbound.protection.outlook.com [40.107.15.112]) (using TLSv1.2 with cipher ECDHE-RSA-AES256-GCM-SHA384 (256/256 bits)) (No client certificate requested) by smtp.subspace.kernel.org (Postfix) with ESMTPS id 1254F12AAD2; Tue, 16 Apr 2024 12:18:37 +0000 (UTC) Authentication-Results: smtp.subspace.kernel.org; arc=fail smtp.client-ip=40.107.15.112 ARC-Seal: i=2; a=rsa-sha256; d=subspace.kernel.org; s=arc-20240116; t=1713269922; cv=fail; b=vGWAzUyFaWOgBDzVqXN7wIENfsnvHw6kDTJ8qFIc3ICcf/QUBITlHRwo0rKeGvvfWUdNeKWoBI1e2JrPkCk5GHkxnBysk+T6atLcqnwAtD/xlMawLdhJFT1K8jz8GAmulPHLwP0cI80Ru3iDD4bPg+VGxX1bRjHoA0V0SBK9VF8= ARC-Message-Signature: i=2; a=rsa-sha256; d=subspace.kernel.org; s=arc-20240116; t=1713269922; c=relaxed/simple; bh=1aoN1xbl/7l9754dcmnA721Yk2m5ifv0RCLzGUA6YGM=; h=From:To:CC:Subject:Date:Message-ID:In-Reply-To:References: Content-Type:MIME-Version; b=agK+BIsiAt15Vhg+ZcsOWYBIrbWfppA8IQFBsPvuPhFDPQW+xAxmQD7mb3zJ0oV3fvAjW59+T+mpYaFXSNjePQcZznepIrxOlEPxcgPNXkMynAuqd1mAXiAQPxJCfUWwPVuCG5YSx5JwhGYWCOW+qet6Kjx4wJUa6uO7RbQ8EVc= ARC-Authentication-Results: i=2; smtp.subspace.kernel.org; dmarc=pass (p=none dis=none) header.from=topic.nl; spf=pass smtp.mailfrom=topic.nl; dkim=pass (2048-bit key) header.d=topic.nl header.i=@topic.nl header.b=shUWSQUt; arc=fail smtp.client-ip=40.107.15.112 Authentication-Results: smtp.subspace.kernel.org; dmarc=pass (p=none dis=none) header.from=topic.nl Authentication-Results: smtp.subspace.kernel.org; spf=pass smtp.mailfrom=topic.nl Authentication-Results: smtp.subspace.kernel.org; dkim=pass (2048-bit key) header.d=topic.nl header.i=@topic.nl header.b="shUWSQUt" ARC-Seal: i=1; a=rsa-sha256; s=arcselector9901; d=microsoft.com; cv=none; b=Zie07Se5jWnuWrB4pPkPuOBO+dMFgGsEMMTwWvoqwWZ9bY1jU+n3J9H3Ga0pDBBxStntRE673qybXx6S9mgli1GY8+4sluk7uH05wu/YLqfmtR6bKxVG8wjmZBN2B420bXVrzNiDQS5QaZdVTgi7kC4oFUjWQaoXJJQo25E5HvzE0VDoQoGUdPQTYkAX7KvKZlGGwNJa9mptbsO0l0CbS60QjPjJfUK8LAjmnMmKStvJo67gsTV8mBZntKIsKggrjzXcKw7SL6cf7C20jf9xctrUGys6+FAf+z+DSDaBMWe4nn4g86hTyUBKMhl9xYADC0wwe96jfs8BRzKUSS8+Eg== ARC-Message-Signature: i=1; a=rsa-sha256; c=relaxed/relaxed; d=microsoft.com; s=arcselector9901; h=From:Date:Subject:Message-ID:Content-Type:MIME-Version:X-MS-Exchange-AntiSpam-MessageData-ChunkCount:X-MS-Exchange-AntiSpam-MessageData-0:X-MS-Exchange-AntiSpam-MessageData-1; bh=QNwBJ+3V/poH/cqTNYIJW1lD5XSkzsOCir07AgsEEfk=; b=eriC23oOvo62Ntf+2YgoUX7Cltjuog/0N7PMixIQ2qSLiWhxLxVSKzZiQ8CzyoJdhgZksb9iKUwuIQqSDvrEvqbCyzeZ6rh8U2c+P/JoALSaBxMTG97SieOh/urJEedHqG+2PB9ZZadhXGVu/qSQHu+VG74cofB3VL2ggsScb+FLVRHFBJsGhMogQNmvZRY5mDKjyCHsc4UhKRfChf6rcr6IIOIi/aX6ddasX7K1PUvwyyg6mL8JoT+MYbMzEGtE+h35d4pPtUX0MBQieJKUdl3cEdtd3uuHZTEy2/iBw/cfH00bCSA5JccHuG8NaAmtQJKWzJ5Axqutqc7Z8+RP3g== ARC-Authentication-Results: i=1; mx.microsoft.com 1; spf=pass (sender ip is 40.69.19.60) smtp.rcpttodomain=vger.kernel.org smtp.mailfrom=topic.nl; dmarc=pass (p=none sp=none pct=100) action=none header.from=topic.nl; dkim=none (message not signed); arc=none (0) DKIM-Signature: v=1; a=rsa-sha256; c=relaxed/relaxed; d=topic.nl; s=selector2; h=From:Date:Subject:Message-ID:Content-Type:MIME-Version:X-MS-Exchange-SenderADCheck; bh=QNwBJ+3V/poH/cqTNYIJW1lD5XSkzsOCir07AgsEEfk=; b=shUWSQUtFXpGX43B9a86/XuoPl2zDcv/+sYPS85TBPOCkKTGUDZboPjjnNSYh8A0EOrtpWxT2SDjEyRnv+TZUoRbZUfmdXXKaRi9eh0phlMF8iKL2uKcvTcEh0gdbzAHTrNIRWa8+QULAUDRaoDjSZLfvmbl4osbdbeHURsWwLiSNs39lHD129RaKrbQQKeqPJbXCT1N5S58S7hezZkoUYjuarXiqESmU1N8DHYIOiKAIUGu6CgDRJhtff3bU9eXZKFnAiUxNx6tWEnJAYBKa4BmqeAMQicI+QKTzF9l28soqwRm/hz1Q6UwDcnWM0t3VJNJMRqD1sCWDtuvbU8GRw== Received: from AS9PR04CA0174.eurprd04.prod.outlook.com (2603:10a6:20b:530::15) by AM9PR04MB8890.eurprd04.prod.outlook.com (2603:10a6:20b:409::24) with Microsoft SMTP Server (version=TLS1_2, cipher=TLS_ECDHE_RSA_WITH_AES_256_GCM_SHA384) id 15.20.7452.50; Tue, 16 Apr 2024 12:18:34 +0000 Received: from AM1PEPF000252DA.eurprd07.prod.outlook.com (2603:10a6:20b:530:cafe::35) by AS9PR04CA0174.outlook.office365.com (2603:10a6:20b:530::15) with Microsoft SMTP Server (version=TLS1_2, cipher=TLS_ECDHE_RSA_WITH_AES_256_GCM_SHA384) id 15.20.7409.45 via Frontend Transport; Tue, 16 Apr 2024 12:18:34 +0000 X-MS-Exchange-Authentication-Results: spf=pass (sender IP is 40.69.19.60) smtp.mailfrom=topic.nl; dkim=none (message not signed) header.d=none;dmarc=pass action=none header.from=topic.nl; Received-SPF: Pass (protection.outlook.com: domain of topic.nl designates 40.69.19.60 as permitted sender) receiver=protection.outlook.com; client-ip=40.69.19.60; helo=westeu100-emailsignatures-cloud.codetwo.com; pr=C Received: from westeu100-emailsignatures-cloud.codetwo.com (40.69.19.60) by AM1PEPF000252DA.mail.protection.outlook.com (10.167.16.52) with Microsoft SMTP Server (version=TLS1_2, cipher=TLS_ECDHE_RSA_WITH_AES_256_GCM_SHA384) id 15.20.7452.22 via Frontend Transport; Tue, 16 Apr 2024 12:18:34 +0000 Received: from EUR03-DBA-obe.outbound.protection.outlook.com (104.47.51.169) by westeu100-emailsignatures-cloud.codetwo.com with CodeTwo SMTP Server (TLS12) via SMTP; Tue, 16 Apr 2024 12:18:32 +0000 Authentication-Results-Original: dkim=none (message not signed) header.d=none;dmarc=none action=none header.from=topic.nl; Received: from AS8PR04MB8644.eurprd04.prod.outlook.com (2603:10a6:20b:42b::12) by VE1PR04MB7230.eurprd04.prod.outlook.com (2603:10a6:800:1ab::20) with Microsoft SMTP Server (version=TLS1_2, cipher=TLS_ECDHE_RSA_WITH_AES_256_GCM_SHA384) id 15.20.7452.50; Tue, 16 Apr 2024 12:18:26 +0000 Received: from AS8PR04MB8644.eurprd04.prod.outlook.com ([fe80::e86d:f110:534e:480a]) by AS8PR04MB8644.eurprd04.prod.outlook.com ([fe80::e86d:f110:534e:480a%4]) with mapi id 15.20.7452.049; Tue, 16 Apr 2024 12:18:26 +0000 From: Mike Looijmans To: linux-pm@vger.kernel.org CC: Mike Looijmans , Sebastian Reichel , linux-kernel@vger.kernel.org Subject: [PATCH v5 5/5] power: supply: ltc3350-charger: Add driver Date: Tue, 16 Apr 2024 14:18:18 +0200 Message-ID: <20240416121818.543896-5-mike.looijmans@topic.nl> X-Mailer: git-send-email 2.34.1 In-Reply-To: <20240416121818.543896-1-mike.looijmans@topic.nl> References: <20240416121818.543896-1-mike.looijmans@topic.nl> <1b153bce-a66a-45ee-a5c6-963ea6fb1c82.949ef384-8293-46b8-903f-40a477c056ae.4a7cccf3-e7cb-4980-be8e-de8bd2795354@emailsignatures365.codetwo.com> X-ClientProxiedBy: AM8P251CA0015.EURP251.PROD.OUTLOOK.COM (2603:10a6:20b:21b::20) To AS8PR04MB8644.eurprd04.prod.outlook.com (2603:10a6:20b:42b::12) Precedence: bulk X-Mailing-List: linux-pm@vger.kernel.org List-Id: List-Subscribe: List-Unsubscribe: MIME-Version: 1.0 X-MS-TrafficTypeDiagnostic: AS8PR04MB8644:EE_|VE1PR04MB7230:EE_|AM1PEPF000252DA:EE_|AM9PR04MB8890:EE_ X-MS-Office365-Filtering-Correlation-Id: 6efb13fa-5b5c-4c33-71a0-08dc5e0f5612 X-MS-Exchange-SenderADCheck: 1 X-MS-Exchange-AntiSpam-Relay: 0 X-Microsoft-Antispam-Untrusted: BCL:0; X-Microsoft-Antispam-Message-Info-Original: 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 X-Forefront-Antispam-Report-Untrusted: CIP:255.255.255.255;CTRY:;LANG:en;SCL:1;SRV:;IPV:NLI;SFV:NSPM;H:AS8PR04MB8644.eurprd04.prod.outlook.com;PTR:;CAT:NONE;SFS:(13230031)(376005)(52116005)(366007)(1800799015)(38350700005);DIR:OUT;SFP:1102; X-MS-Exchange-Transport-CrossTenantHeadersStamped: VE1PR04MB7230 X-CodeTwo-MessageID: 5cdcea80-bff0-4a07-a4cb-919c7428c8f7.20240416121832@westeu100-emailsignatures-cloud.codetwo.com X-CodeTwoProcessed: true X-EOPAttributedMessage: 0 X-MS-Exchange-Transport-CrossTenantHeadersStripped: AM1PEPF000252DA.eurprd07.prod.outlook.com X-MS-PublicTrafficType: Email X-MS-Office365-Filtering-Correlation-Id-Prvs: c2f35af9-f6bf-4a54-a3c5-08dc5e0f5134 X-Microsoft-Antispam: BCL:0; X-Microsoft-Antispam-Message-Info: =?utf-8?q?dQcHh2QlSQmRSD+L02P7QNICcD1ytG7?= =?utf-8?q?9zpszdytpSXJ6yZniUZO+WY6FfZZPwVKVTQh9NrmVhK4pnAwoDVtdzcAx6QstBSY1?= =?utf-8?q?eBGx2f3TWy36DE0MUqlkZDKp/j7MhXAma5HftN7rNh7lba0ieJY9raxQ+iYqwEb6T?= =?utf-8?q?39anBEafwsqyWmBI+VKfECVNLaXSFcHrWhdR5fs0b/6mfhXYjuKkVuSx3kZhU8h4S?= =?utf-8?q?MtYZgVkM8lll4jBP+AvcQPkR4syAGXbRxACPVxD253VRZi794sF6yA5QB90aE3pGr?= =?utf-8?q?jJhDSuJp+lhLgvX6Th1DWMq75korSScneyxGb0KoUY4TdYO6i/XwAHtsNEu8TpuKw?= =?utf-8?q?A8CtsLeoeOtgBt9nKiglqg2uA8P6SxlTcE9NmS9A0l73kbP0Vu4spVALaVyPy9kb5?= =?utf-8?q?ksq270B8s/fXdFtxprR/urnTkivLyIVPXjfLaf7ik25eTwDD5+vTgoEsTuJLQVHel?= =?utf-8?q?1YBTerAI0ert8Mm3O4kwZ3XsMAEPkKU/7fU9LtxnruIKFJgEZ9BrCn14Wg7av41h0?= =?utf-8?q?JiAKDdS9iwVG9aA7eeewPH20+BEwN9BYicTHICsWKGHpgkrjwqAPFHcqBCVN4d5M/?= =?utf-8?q?/AfPhEnsqVTkL71V1/j33U/5d8hRs090BweuR44aEG3XNIfWFMHDnJbBStPi6slVX?= =?utf-8?q?IXOAEuRtYdYrLaqf1MGSUYYw7najW0G7MEAxxec1ziD9/2VLfjwLL3PjfwCvzlJF7?= =?utf-8?q?YcHPeLmMaACY9hjJAeZMtM5eAESHWUMJ2j/Yco/hpZTN7XKMAUr4BQAuKybR2NKn9?= =?utf-8?q?L/sQflSJhAgtekCtpRiOjhdhiU/D27mw77m3lRO+nRwyQntoV9DPZLkbi1sPbxomJ?= =?utf-8?q?Z5xp7938fzfaO6eLxUbYeAmv1y5KM9+iZ3ZtmnNUSxZXpCVorotckOFa09d1BsDWZ?= =?utf-8?q?LfLx63+PluCQTMLLwglkaA2vs6MsHAk8iGiZNrxjyqDPZshtZrqX7OTIjz2if3crl?= =?utf-8?q?2qim5ZGugMDNikrAMrqB6VVC9Im+nV1oWVmWup97gQtZ+/06hEZUEaVumbZkvOC3q?= =?utf-8?q?lBH6AiU6NuL0ILH/W+TtHemMUvTbwumDhDnmSen2GW10WXepBEWssEsTFUGs7sj7A?= =?utf-8?q?hVVMalqg+Nud4DlWMKMx65IFqzuLPXNZL8VyFib+Fnmv/9lzluxRYDR8e/Ydob03i?= =?utf-8?q?Y+5Am9YfyQ7+0cv23tF4hMwjgXzuNeRe5aGx8F0QWWBsKedfQ4hxXf8xqDFQgXM+4?= =?utf-8?q?TVHOtkY5LG9zTsHuaOqQ0L3+QjA7011f2XlNfEnMmT0x9bPmawEDutQxlUZKqfiWo?= =?utf-8?q?3CkTDNm5HiqBo?= X-Forefront-Antispam-Report: CIP:40.69.19.60;CTRY:IE;LANG:en;SCL:1;SRV:;IPV:NLI;SFV:NSPM;H:westeu100-emailsignatures-cloud.codetwo.com;PTR:westeu100-emailsignatures-cloud.codetwo.com;CAT:NONE;SFS:(13230031)(82310400014)(36860700004)(376005)(1800799015);DIR:OUT;SFP:1102; X-OriginatorOrg: topic.nl X-MS-Exchange-CrossTenant-OriginalArrivalTime: 16 Apr 2024 12:18:34.0243 (UTC) X-MS-Exchange-CrossTenant-Network-Message-Id: 6efb13fa-5b5c-4c33-71a0-08dc5e0f5612 X-MS-Exchange-CrossTenant-Id: 449607a5-3517-482d-8d16-41dd868cbda3 X-MS-Exchange-CrossTenant-OriginalAttributedTenantConnectingIp: TenantId=449607a5-3517-482d-8d16-41dd868cbda3;Ip=[40.69.19.60];Helo=[westeu100-emailsignatures-cloud.codetwo.com] X-MS-Exchange-CrossTenant-AuthSource: AM1PEPF000252DA.eurprd07.prod.outlook.com X-MS-Exchange-CrossTenant-AuthAs: Anonymous X-MS-Exchange-CrossTenant-FromEntityHeader: HybridOnPrem X-MS-Exchange-Transport-CrossTenantHeadersStamped: AM9PR04MB8890 The LTC3350 is a backup power controller that can charge and monitor a series stack of one to four supercapacitors. Signed-off-by: Mike Looijmans --- Changes in v5: Fix ltc3350_set_scaled() arguments in "store" routines Measurement values are signed Report technology as "Capacitor" Report "full" when "capgd" asserts Move charge current to "current_now" of capacitor Add ABI documentation Changes in v4: Split into "charger" and "capacitor" parts Use (new) standard properties Header include fixups Explain local "scale" units Drop i2c_check_functionality Use dev_err_probe Use dev_fwnode Drop of_match_ptr Changes in v2: Duplicate "vin_ov" and "vin_uv" attributes .../ABI/testing/sysfs-class-power-ltc3350 | 88 ++ drivers/power/supply/Kconfig | 10 + drivers/power/supply/Makefile | 1 + drivers/power/supply/ltc3350-charger.c | 789 ++++++++++++++++++ 4 files changed, 888 insertions(+) create mode 100644 Documentation/ABI/testing/sysfs-class-power-ltc3350 create mode 100644 drivers/power/supply/ltc3350-charger.c diff --git a/Documentation/ABI/testing/sysfs-class-power-ltc3350 b/Documentation/ABI/testing/sysfs-class-power-ltc3350 new file mode 100644 index 000000000000..d4a2bb0fb62b --- /dev/null +++ b/Documentation/ABI/testing/sysfs-class-power-ltc3350 @@ -0,0 +1,88 @@ +What: /sys/class/power_supply/ltc3350/charge_status +Date: April 2024 +KernelVersion: 6.9 +Description: + Detailed charge status information as reported by the chip. This + returns the raw register value in hex. + + Access: Read + +What: /sys/class/power_supply/ltc3350/vshunt +Date: April 2024 +KernelVersion: 6.9 +Description: + Voltage for "shunting" the capacitors in the stack. When the + capacitor voltage is above this value, the chip will discharge + the excess voltage using a shunt resistor. + This is typically used to limit the voltage on a single cell, + to compensate for imbalance and prevent damaging the capacitor + while charging. It can also be used to forcibly discharge the + capacitors. + + Access: Read, Write + + Valid values: In microvolts, defaults to 2.7V + +What: /sys/class/power_supply/ltc3350/gpi +Date: April 2024 +KernelVersion: 6.9 +Description: + General purpose input voltage. Returns a single measurement. + + Access: Read + + Valid values: In microvolts + +What: /sys/class/power_supply/ltc3350/gpi_ov +Date: April 2024 +KernelVersion: 6.9 +Description: + General purpose input voltage overvoltage level. Triggers an + alert for userspace when the voltage goes above this value. + + Access: Read, Write + + Valid values: In microvolts + +What: /sys/class/power_supply/ltc3350/gpi_uv +Date: April 2024 +KernelVersion: 6.9 +Description: + General purpose input voltage undervoltage level. Triggers an + alert for userspace when the voltage drops below this value. + + Access: Read, Write + + Valid values: In microvolts + +What: /sys/class/power_supply/ltc3350/vin +Date: April 2024 +KernelVersion: 6.9 +Description: + Charger input voltage. Returns a single measurement. + + Access: Read + + Valid values: In microvolts + +What: /sys/class/power_supply/ltc3350/vin_ov +Date: April 2024 +KernelVersion: 6.9 +Description: + Input voltage overvoltage level. Triggers an alert for userspace + when the voltage goes above this value. + + Access: Read, Write + + Valid values: In microvolts + +What: /sys/class/power_supply/ltc3350/vin_uv +Date: April 2024 +KernelVersion: 6.9 +Description: + Input voltage undervoltage level. Triggers an alert for + userspace when the voltage drops below this value. + + Access: Read, Write + + Valid values: In microvolts diff --git a/drivers/power/supply/Kconfig b/drivers/power/supply/Kconfig index 3e31375491d5..7cb1a66e522d 100644 --- a/drivers/power/supply/Kconfig +++ b/drivers/power/supply/Kconfig @@ -514,6 +514,16 @@ config CHARGER_LT3651 Say Y to include support for the Analog Devices (Linear Technology) LT3651 battery charger which reports its status via GPIO lines. +config CHARGER_LTC3350 + tristate "LTC3350 Supercapacitor Backup Controller and System Monitor" + depends on I2C + select REGMAP_I2C + select I2C_SMBUS + help + Say Y to include support for the Analog Devices (Linear Technology) + LTC3350 Supercapacitor Backup Controller and System Monitor connected + to I2C. + config CHARGER_LTC4162L tristate "LTC4162-L charger" depends on I2C diff --git a/drivers/power/supply/Makefile b/drivers/power/supply/Makefile index 58b567278034..a8d618e4ac91 100644 --- a/drivers/power/supply/Makefile +++ b/drivers/power/supply/Makefile @@ -72,6 +72,7 @@ obj-$(CONFIG_CHARGER_LP8788) += lp8788-charger.o obj-$(CONFIG_CHARGER_GPIO) += gpio-charger.o obj-$(CONFIG_CHARGER_MANAGER) += charger-manager.o obj-$(CONFIG_CHARGER_LT3651) += lt3651-charger.o +obj-$(CONFIG_CHARGER_LTC3350) += ltc3350-charger.o obj-$(CONFIG_CHARGER_LTC4162L) += ltc4162-l-charger.o obj-$(CONFIG_CHARGER_MAX14577) += max14577_charger.o obj-$(CONFIG_CHARGER_DETECTOR_MAX14656) += max14656_charger_detector.o diff --git a/drivers/power/supply/ltc3350-charger.c b/drivers/power/supply/ltc3350-charger.c new file mode 100644 index 000000000000..55b8a3922b4a --- /dev/null +++ b/drivers/power/supply/ltc3350-charger.c @@ -0,0 +1,789 @@ +// SPDX-License-Identifier: GPL-2.0-or-later +/* + * Driver for Analog Devices (Linear Technology) LTC3350 + * High Current Supercapacitor Backup Controller and System Monitor + * Copyright (C) 2024, Topic Embedded Products + */ + +#include +#include +#include +#include +#include +#include +#include +#include + +/* Registers (names based on what datasheet uses) */ +#define LTC3350_REG_CLR_ALARMS 0x00 +#define LTC3350_REG_MSK_ALARMS 0x01 +#define LTC3350_REG_MSK_MON_STATUS 0x02 +#define LTC3350_REG_CAP_ESR_PER 0x04 +#define LTC3350_REG_VCAPFB_DAC 0x05 +#define LTC3350_REG_VSHUNT 0x06 +#define LTC3350_REG_CAP_UV_LVL 0x07 +#define LTC3350_REG_CAP_OV_LVL 0x08 +#define LTC3350_REG_GPI_UV_LVL 0x09 +#define LTC3350_REG_GPI_OV_LVL 0x0A +#define LTC3350_REG_VIN_UV_LVL 0x0B +#define LTC3350_REG_VIN_OV_LVL 0x0C +#define LTC3350_REG_VCAP_UV_LVL 0x0D +#define LTC3350_REG_VCAP_OV_LVL 0x0E +#define LTC3350_REG_VOUT_UV_LVL 0x0F +#define LTC3350_REG_VOUT_OV_LVL 0x10 +#define LTC3350_REG_IIN_OC_LVL 0x11 +#define LTC3350_REG_ICHG_UC_LVL 0x12 +#define LTC3350_REG_DTEMP_COLD_LVL 0x13 +#define LTC3350_REG_DTEMP_HOT_LVL 0x14 +#define LTC3350_REG_ESR_HI_LVL 0x15 +#define LTC3350_REG_CAP_LO_LVL 0x16 +#define LTC3350_REG_CTL_REG 0x17 +#define LTC3350_REG_NUM_CAPS 0x1A +#define LTC3350_REG_CHRG_STATUS 0x1B +#define LTC3350_REG_MON_STATUS 0x1C +#define LTC3350_REG_ALARM_REG 0x1D +#define LTC3350_REG_MEAS_CAP 0x1E +#define LTC3350_REG_MEAS_ESR 0x1F +#define LTC3350_REG_MEAS_VCAP1 0x20 +#define LTC3350_REG_MEAS_VCAP2 0x21 +#define LTC3350_REG_MEAS_VCAP3 0x22 +#define LTC3350_REG_MEAS_VCAP4 0x23 +#define LTC3350_REG_MEAS_GPI 0x24 +#define LTC3350_REG_MEAS_VIN 0x25 +#define LTC3350_REG_MEAS_VCAP 0x26 +#define LTC3350_REG_MEAS_VOUT 0x27 +#define LTC3350_REG_MEAS_IIN 0x28 +#define LTC3350_REG_MEAS_ICHG 0x29 +#define LTC3350_REG_MEAS_DTEMP 0x2A + +/* LTC3350_REG_CLR_ALARMS, LTC3350_REG_MASK_ALARMS, LTC3350_REG_ALARM_REG */ +#define LTC3350_MSK_CAP_UV BIT(0) /* capacitor undervoltage alarm */ +#define LTC3350_MSK_CAP_OV BIT(1) /* capacitor overvoltage alarm */ +#define LTC3350_MSK_GPI_UV BIT(2) /* GPI undervoltage alarm */ +#define LTC3350_MSK_GPI_OV BIT(3) /* GPI overvoltage alarm */ +#define LTC3350_MSK_VIN_UV BIT(4) /* VIN undervoltage alarm */ +#define LTC3350_MSK_VIN_OV BIT(5) /* VIN overvoltage alarm */ +#define LTC3350_MSK_VCAP_UV BIT(6) /* VCAP undervoltage alarm */ +#define LTC3350_MSK_VCAP_OV BIT(7) /* VCAP overvoltage alarm */ +#define LTC3350_MSK_VOUT_UV BIT(8) /* VOUT undervoltage alarm */ +#define LTC3350_MSK_VOUT_OV BIT(9) /* VOUT overvoltage alarm */ +#define LTC3350_MSK_IIN_OC BIT(10) /* input overcurrent alarm */ +#define LTC3350_MSK_ICHG_UC BIT(11) /* charge undercurrent alarm */ +#define LTC3350_MSK_DTEMP_COLD BIT(12) /* die temperature cold alarm */ +#define LTC3350_MSK_DTEMP_HOT BIT(13) /* die temperature hot alarm */ +#define LTC3350_MSK_ESR_HI BIT(14) /* ESR high alarm */ +#define LTC3350_MSK_CAP_LO BIT(15) /* capacitance low alarm */ + +/* LTC3350_REG_MSK_MON_STATUS masks */ +#define LTC3350_MSK_MON_CAPESR_ACTIVE BIT(0) +#define LTC3350_MSK_MON_CAPESR_SCHEDULED BIT(1) +#define LTC3350_MSK_MON_CAPESR_PENDING BIT(2) +#define LTC3350_MSK_MON_CAP_DONE BIT(3) +#define LTC3350_MSK_MON_ESR_DONE BIT(4) +#define LTC3350_MSK_MON_CAP_FAILED BIT(5) +#define LTC3350_MSK_MON_ESR_FAILED BIT(6) +#define LTC3350_MSK_MON_POWER_FAILED BIT(8) +#define LTC3350_MSK_MON_POWER_RETURNED BIT(9) + +/* LTC3350_REG_CTL_REG */ +/* Begin a capacitance and ESR measurement when possible */ +#define LTC3350_CTL_STRT_CAPESR BIT(0) +/* A one in this bit location enables the input buffer on the GPI pin */ +#define LTC3350_CTL_GPI_BUFFER_EN BIT(1) +/* Stops an active capacitance/ESR measurement */ +#define LTC3350_CTL_STOP_CAPESR BIT(2) +/* Increases capacitor measurement resolution by 100x for smaller capacitors */ +#define LTC3350_CTL_CAP_SCALE BIT(3) + +/* LTC3350_REG_CHRG_STATUS */ +#define LTC3350_CHRG_STEPDOWN BIT(0) /* Synchronous controller in step-down mode (charging) */ +#define LTC3350_CHRG_STEPUP BIT(1) /* Synchronous controller in step-up mode (backup) */ +#define LTC3350_CHRG_CV BIT(2) /* The charger is in constant voltage mode */ +#define LTC3350_CHRG_UVLO BIT(3) /* The charger is in undervoltage lockout */ +#define LTC3350_CHRG_INPUT_ILIM BIT(4) /* The charger is in input current limit */ +#define LTC3350_CHRG_CAPPG BIT(5) /* The capacitor voltage is above power good threshold */ +#define LTC3350_CHRG_SHNT BIT(6) /* The capacitor manager is shunting */ +#define LTC3350_CHRG_BAL BIT(7) /* The capacitor manager is balancing */ +#define LTC3350_CHRG_DIS BIT(8) /* Charger disabled for capacitance measurement */ +#define LTC3350_CHRG_CI BIT(9) /* The charger is in constant current mode */ +#define LTC3350_CHRG_PFO BIT(11) /* Input voltage is below PFI threshold */ + +/* LTC3350_REG_MON_STATUS */ +#define LTC3350_MON_CAPESR_ACTIVE BIT(0) /* Capacitance/ESR measurement in progress */ +#define LTC3350_MON_CAPESR_SCHEDULED BIT(1) /* Waiting programmed time */ +#define LTC3350_MON_CAPESR_PENDING BIT(2) /* Waiting for satisfactory conditions */ +#define LTC3350_MON_CAP_DONE BIT(3) /* Capacitance measurement has completed */ +#define LTC3350_MON_ESR_DONE BIT(4) /* ESR Measurement has completed */ +#define LTC3350_MON_CAP_FAILED BIT(5) /* Last capacitance measurement failed */ +#define LTC3350_MON_ESR_FAILED BIT(6) /* Last ESR measurement failed */ +#define LTC3350_MON_POWER_FAILED BIT(8) /* Unable to charge */ +#define LTC3350_MON_POWER_RETURNED BIT(9) /* Able to charge */ + + +struct ltc3350_info { + struct i2c_client *client; + struct regmap *regmap; + struct power_supply *charger; + struct power_supply *capacitor; + u32 rsnsc; /* Series resistor that sets charge current, microOhm */ + u32 rsnsi; /* Series resistor to measure input current, microOhm */ +}; + +/* + * About LTC3350 "alarm" functions: Setting a bit in the LTC3350_REG_MSK_ALARMS + * register enables the alarm. The alarm will trigger an SMBALERT only once. + * To reset the alarm, write a "1" bit to LTC3350_REG_CLR_ALARMS. Then the alarm + * will trigger another SMBALERT when conditions are met (may be immediately). + * After writing to one of the corresponding level registers, enable the alarm, + * so that a UEVENT triggers when the alarm goes off. + */ +static void ltc3350_enable_alarm(struct ltc3350_info *info, unsigned int reg) +{ + unsigned int mask; + + /* Register locations correspond to alarm mask bits */ + mask = BIT(reg - LTC3350_REG_CAP_UV_LVL); + /* Clear the alarm bit so it may trigger again */ + regmap_write(info->regmap, LTC3350_REG_CLR_ALARMS, mask); + /* Enable the alarm */ + regmap_update_bits(info->regmap, LTC3350_REG_MSK_ALARMS, mask, mask); +} + +/* Convert enum value to POWER_SUPPLY_STATUS value */ +static int ltc3350_state_decode(unsigned int value) +{ + if (value & LTC3350_CHRG_STEPUP) + return POWER_SUPPLY_STATUS_DISCHARGING; /* running on backup */ + + if (value & LTC3350_CHRG_PFO) + return POWER_SUPPLY_STATUS_NOT_CHARGING; + + if (value & LTC3350_CHRG_STEPDOWN) { + if (value & LTC3350_CHRG_CAPPG) + return POWER_SUPPLY_STATUS_FULL; + + return POWER_SUPPLY_STATUS_CHARGING; + } + + /* Not in step down? Must be full then (never seen this) */ + return POWER_SUPPLY_STATUS_FULL; +}; + +static int ltc3350_get_status(struct ltc3350_info *info, union power_supply_propval *val) +{ + unsigned int regval; + int ret; + + ret = regmap_read(info->regmap, LTC3350_REG_CHRG_STATUS, ®val); + if (ret) + return ret; + + val->intval = ltc3350_state_decode(regval); + + return 0; +} + +static int ltc3350_charge_status_decode(unsigned int value) +{ + if (!(value & LTC3350_CHRG_STEPDOWN)) + return POWER_SUPPLY_CHARGE_TYPE_NONE; + + /* constant voltage is "topping off" */ + if (value & LTC3350_CHRG_CV) + return POWER_SUPPLY_CHARGE_TYPE_TRICKLE; + + /* input limiter */ + if (value & LTC3350_CHRG_INPUT_ILIM) + return POWER_SUPPLY_CHARGE_TYPE_ADAPTIVE; + + /* constant current is "fast" */ + if (value & LTC3350_CHRG_CI) + return POWER_SUPPLY_CHARGE_TYPE_FAST; + + return POWER_SUPPLY_CHARGE_TYPE_UNKNOWN; +} + +static int ltc3350_get_charge_type(struct ltc3350_info *info, union power_supply_propval *val) +{ + unsigned int regval; + int ret; + + ret = regmap_read(info->regmap, LTC3350_REG_CHRG_STATUS, ®val); + if (ret) + return ret; + + val->intval = ltc3350_charge_status_decode(regval); + + return 0; +} + +static int ltc3350_get_online(struct ltc3350_info *info, union power_supply_propval *val) +{ + unsigned int regval; + int ret; + + ret = regmap_read(info->regmap, LTC3350_REG_MON_STATUS, ®val); + if (ret) + return ret; + + /* indicates if input voltage is sufficient to charge */ + val->intval = !!(regval & LTC3350_MON_POWER_RETURNED); + + return 0; +} + +static int ltc3350_get_scaled(struct ltc3350_info *info, unsigned int reg, + int scale, int *value) +{ + unsigned int regval; + int ret; + + ret = regmap_read(info->regmap, reg, ®val); + if (ret) + return ret; + + /* + * The "scale" here is 10 μV per LSB, this allows all calculations to + * be done in 32-bit integer without overflow. This converts the + * register value to μV. + */ + *value = sign_extend32(regval, 15) * scale / 10; + + return 0; +} + +static int ltc3350_set_scaled(struct ltc3350_info *info, unsigned int reg, int scale, int value) +{ + int ret; + + value *= 10; + value = DIV_ROUND_CLOSEST(value, scale); + + ret = regmap_write(info->regmap, reg, value); + if (ret) + return ret; + + /* When writing to one of the LVL registers, update the alarm mask */ + if (reg >= LTC3350_REG_CAP_UV_LVL && reg <= LTC3350_REG_CAP_LO_LVL) + ltc3350_enable_alarm(info, reg); + + return 0; +} + +static int ltc3350_get_input_current(struct ltc3350_info *info, union power_supply_propval *val) +{ + unsigned int regval; + int ret; + + ret = regmap_read(info->regmap, LTC3350_REG_MEAS_IIN, ®val); + if (ret) + return ret; + + /* 1.983µV/RSNSI amperes per LSB */ + ret = sign_extend32(regval, 15) * 19830; + ret /= (int)info->rsnsi; + ret *= 100; + + val->intval = ret; + + return 0; +} + +static int ltc3350_get_icharge(struct ltc3350_info *info, union power_supply_propval *val) +{ + unsigned int regval; + int ret; + + ret = regmap_read(info->regmap, LTC3350_REG_MEAS_ICHG, ®val); + if (ret) + return ret; + + /* 1.983µV/RSNSC amperes per LSB */ + ret = sign_extend32(regval, 15) * 19830; + ret /= (int)info->rsnsc; + ret *= 100; + + val->intval = ret; + + return 0; +} + +static int ltc3350_get_icharge_max(struct ltc3350_info *info, union power_supply_propval *val) +{ + /* I_CHG(MAX) = 32mV / RSNSC (Ampere) */ + val->intval = 3200000000U / (info->rsnsc / 10); + + return 0; +} + +static int ltc3350_get_iin_max(struct ltc3350_info *info, union power_supply_propval *val) +{ + /* I_IN(MAX) = 32mV / RSNSI (Ampere) */ + val->intval = 3200000000U / (info->rsnsi / 10); + + return 0; +} + + +static int ltc3350_get_die_temp(struct ltc3350_info *info, unsigned int reg, + union power_supply_propval *val) +{ + unsigned int regval; + int ret; + + ret = regmap_read(info->regmap, reg, ®val); + if (ret) + return ret; + + /* 0.028°C per LSB – 251.4°C */ + ret = 280 * sign_extend32(regval, 15); + ret /= 100; /* Centidegrees scale */ + ret -= 25140; + val->intval = ret; + + return 0; +} + +static int ltc3350_set_die_temp(struct ltc3350_info *info, unsigned int reg, int val) +{ + unsigned int regval; + int ret; + + /* 0.028°C per LSB – 251.4°C */ + regval = val + 25140; + regval *= 100; + regval /= 280; + + ret = regmap_write(info->regmap, reg, regval); + if (ret) + return ret; + + ltc3350_enable_alarm(info, reg); + return 0; +} + +static int ltc3350_get_num_caps(struct ltc3350_info *info, union power_supply_propval *val) +{ + unsigned int regval; + int ret; + + ret = regmap_read(info->regmap, LTC3350_REG_NUM_CAPS, ®val); + if (ret) + return ret; + + val->intval = regval + 1; + + return 0; +} + + +/* Custom properties */ +static ssize_t ltc3350_attr_show(struct device *dev, + struct device_attribute *attr, char *buf, + unsigned int reg, int scale) +{ + struct power_supply *psy = to_power_supply(dev); + struct ltc3350_info *info = power_supply_get_drvdata(psy); + int value; + int ret; + + ret = ltc3350_get_scaled(info, reg, scale, &value); + if (ret) + return ret; + + return sprintf(buf, "%d\n", value); +} + +static ssize_t ltc3350_attr_store(struct device *dev, struct device_attribute *attr, + const char *buf, size_t count, + unsigned int reg, unsigned int scale) +{ + struct power_supply *psy = to_power_supply(dev); + struct ltc3350_info *info = power_supply_get_drvdata(psy); + unsigned long val; + int ret; + + ret = kstrtoul(buf, 10, &val); + if (ret) + return ret; + + ret = ltc3350_set_scaled(info, reg, scale, val); + if (ret) + return ret; + + return count; +} + +#define LTC3350_DEVICE_ATTR_RO(_name, _reg, _scale) \ +static ssize_t _name##_show(struct device *dev, struct device_attribute *attr, \ + char *buf) \ +{ \ + return ltc3350_attr_show(dev, attr, buf, _reg, _scale); \ +} \ +static DEVICE_ATTR_RO(_name) + +#define LTC3350_DEVICE_ATTR_RW(_name, _reg, _scale) \ +static ssize_t _name##_show(struct device *dev, struct device_attribute *attr, \ + char *buf) \ +{ \ + return ltc3350_attr_show(dev, attr, buf, _reg, _scale); \ +} \ +static ssize_t _name##_store(struct device *dev, struct device_attribute *attr, \ + const char *buf, size_t count) \ +{ \ + return ltc3350_attr_store(dev, attr, buf, count, _reg, _scale); \ +} \ +static DEVICE_ATTR_RW(_name) + +/* Shunt voltage, 183.5μV per LSB */ +LTC3350_DEVICE_ATTR_RW(vshunt, LTC3350_REG_VSHUNT, 1835); + +/* General purpose input, 183.5μV per LSB */ +LTC3350_DEVICE_ATTR_RO(gpi, LTC3350_REG_MEAS_GPI, 1835); +LTC3350_DEVICE_ATTR_RW(gpi_uv, LTC3350_REG_GPI_UV_LVL, 1835); +LTC3350_DEVICE_ATTR_RW(gpi_ov, LTC3350_REG_GPI_OV_LVL, 1835); + +/* Input voltage, 2.21mV per LSB */ +LTC3350_DEVICE_ATTR_RO(vin, LTC3350_REG_MEAS_VIN, 22100); +LTC3350_DEVICE_ATTR_RW(vin_uv, LTC3350_REG_VIN_UV_LVL, 22100); +LTC3350_DEVICE_ATTR_RW(vin_ov, LTC3350_REG_VIN_OV_LVL, 22100); + +static ssize_t charge_status_show(struct device *dev, struct device_attribute *attr, char *buf) +{ + struct power_supply *psy = to_power_supply(dev); + struct ltc3350_info *info = power_supply_get_drvdata(psy); + unsigned int regval; + int ret; + + ret = regmap_read(info->regmap, LTC3350_REG_CHRG_STATUS, ®val); + if (ret) + return ret; + + return sprintf(buf, "0x%x\n", regval); +} +static DEVICE_ATTR_RO(charge_status); + +static struct attribute *ltc3350_sysfs_entries[] = { + &dev_attr_vshunt.attr, + &dev_attr_gpi.attr, + &dev_attr_gpi_uv.attr, + &dev_attr_gpi_ov.attr, + &dev_attr_vin.attr, + &dev_attr_vin_uv.attr, + &dev_attr_vin_ov.attr, + &dev_attr_charge_status.attr, + NULL, +}; + +static const struct attribute_group ltc3350_attr_group = { + .name = NULL, /* put in device directory */ + .attrs = ltc3350_sysfs_entries, +}; + +static const struct attribute_group *ltc3350_attr_groups[] = { + <c3350_attr_group, + NULL, +}; + +static int ltc3350_get_property(struct power_supply *psy, enum power_supply_property psp, + union power_supply_propval *val) +{ + struct ltc3350_info *info = power_supply_get_drvdata(psy); + + switch (psp) { + case POWER_SUPPLY_PROP_STATUS: + return ltc3350_get_status(info, val); + case POWER_SUPPLY_PROP_CHARGE_TYPE: + return ltc3350_get_charge_type(info, val); + case POWER_SUPPLY_PROP_ONLINE: + return ltc3350_get_online(info, val); + case POWER_SUPPLY_PROP_VOLTAGE_NOW: + return ltc3350_get_scaled(info, LTC3350_REG_MEAS_VOUT, 22100, &val->intval); + case POWER_SUPPLY_PROP_VOLTAGE_MIN: + return ltc3350_get_scaled(info, LTC3350_REG_VOUT_UV_LVL, 22100, &val->intval); + case POWER_SUPPLY_PROP_VOLTAGE_MAX: + return ltc3350_get_scaled(info, LTC3350_REG_VOUT_OV_LVL, 22100, &val->intval); + case POWER_SUPPLY_PROP_CURRENT_NOW: + return ltc3350_get_input_current(info, val); + case POWER_SUPPLY_PROP_CONSTANT_CHARGE_CURRENT_MAX: + return ltc3350_get_icharge_max(info, val); + case POWER_SUPPLY_PROP_INPUT_CURRENT_LIMIT: + return ltc3350_get_iin_max(info, val); + case POWER_SUPPLY_PROP_TEMP: + return ltc3350_get_die_temp(info, LTC3350_REG_MEAS_DTEMP, val); + case POWER_SUPPLY_PROP_TEMP_ALERT_MIN: + return ltc3350_get_die_temp(info, LTC3350_REG_DTEMP_COLD_LVL, val); + case POWER_SUPPLY_PROP_TEMP_ALERT_MAX: + return ltc3350_get_die_temp(info, LTC3350_REG_DTEMP_HOT_LVL, val); + default: + return -EINVAL; + } +} + +static int ltc3350_set_property(struct power_supply *psy, enum power_supply_property psp, + const union power_supply_propval *val) +{ + struct ltc3350_info *info = power_supply_get_drvdata(psy); + + switch (psp) { + case POWER_SUPPLY_PROP_TEMP_ALERT_MIN: + return ltc3350_set_die_temp(info, LTC3350_REG_DTEMP_COLD_LVL, val->intval); + case POWER_SUPPLY_PROP_TEMP_ALERT_MAX: + return ltc3350_set_die_temp(info, LTC3350_REG_DTEMP_HOT_LVL, val->intval); + default: + return -EINVAL; + } +} + +static int ltc3350_property_is_writeable(struct power_supply *psy, enum power_supply_property psp) +{ + switch (psp) { + case POWER_SUPPLY_PROP_VOLTAGE_MIN: + case POWER_SUPPLY_PROP_VOLTAGE_MAX: + case POWER_SUPPLY_PROP_TEMP_ALERT_MIN: + case POWER_SUPPLY_PROP_TEMP_ALERT_MAX: + case POWER_SUPPLY_PROP_CELL_VOLTAGE_MIN: + case POWER_SUPPLY_PROP_CELL_VOLTAGE_MAX: + return 1; + default: + return 0; + } +} + +/* Charger power supply property routines */ +static enum power_supply_property ltc3350_properties[] = { + POWER_SUPPLY_PROP_STATUS, + POWER_SUPPLY_PROP_CHARGE_TYPE, + POWER_SUPPLY_PROP_ONLINE, + POWER_SUPPLY_PROP_VOLTAGE_NOW, + POWER_SUPPLY_PROP_CURRENT_NOW, + POWER_SUPPLY_PROP_CONSTANT_CHARGE_CURRENT_MAX, + POWER_SUPPLY_PROP_INPUT_CURRENT_LIMIT, + POWER_SUPPLY_PROP_TEMP, + POWER_SUPPLY_PROP_TEMP_ALERT_MIN, + POWER_SUPPLY_PROP_TEMP_ALERT_MAX, +}; + +static const struct power_supply_desc ltc3350_desc = { + .name = "ltc3350", + .type = POWER_SUPPLY_TYPE_MAINS, + .properties = ltc3350_properties, + .num_properties = ARRAY_SIZE(ltc3350_properties), + .get_property = ltc3350_get_property, + .set_property = ltc3350_set_property, + .property_is_writeable = ltc3350_property_is_writeable, +}; + +static int ltc3350_capacitor_get_property(struct power_supply *psy, enum power_supply_property psp, + union power_supply_propval *val) +{ + struct ltc3350_info *info = power_supply_get_drvdata(psy); + + switch (psp) { + case POWER_SUPPLY_PROP_STATUS: + return ltc3350_get_status(info, val); + case POWER_SUPPLY_PROP_TECHNOLOGY: + val->intval = POWER_SUPPLY_TECHNOLOGY_CAPACITOR; + return 0; + case POWER_SUPPLY_PROP_VOLTAGE_NOW: + /* Capacitor stack voltage, 1.476 mV per LSB */ + return ltc3350_get_scaled(info, LTC3350_REG_MEAS_VCAP, 14760, &val->intval); + case POWER_SUPPLY_PROP_VOLTAGE_MIN: + return ltc3350_get_scaled(info, LTC3350_REG_VCAP_UV_LVL, 14760, &val->intval); + case POWER_SUPPLY_PROP_VOLTAGE_MAX: + return ltc3350_get_scaled(info, LTC3350_REG_VCAP_OV_LVL, 14760, &val->intval); + case POWER_SUPPLY_PROP_CURRENT_NOW: + return ltc3350_get_icharge(info, val); + case POWER_SUPPLY_PROP_NUMBER_OF_SERIAL_CELLS: + return ltc3350_get_num_caps(info, val); + case POWER_SUPPLY_PROP_CELL1_VOLTAGE_NOW: + /* Single capacitor voltages, 183.5μV per LSB */ + return ltc3350_get_scaled(info, LTC3350_REG_MEAS_VCAP1, 1835, &val->intval); + case POWER_SUPPLY_PROP_CELL2_VOLTAGE_NOW: + return ltc3350_get_scaled(info, LTC3350_REG_MEAS_VCAP2, 1835, &val->intval); + case POWER_SUPPLY_PROP_CELL3_VOLTAGE_NOW: + return ltc3350_get_scaled(info, LTC3350_REG_MEAS_VCAP3, 1835, &val->intval); + case POWER_SUPPLY_PROP_CELL4_VOLTAGE_NOW: + return ltc3350_get_scaled(info, LTC3350_REG_MEAS_VCAP4, 1835, &val->intval); + case POWER_SUPPLY_PROP_CELL_VOLTAGE_MIN: + return ltc3350_get_scaled(info, LTC3350_REG_CAP_UV_LVL, 1835, &val->intval); + case POWER_SUPPLY_PROP_CELL_VOLTAGE_MAX: + return ltc3350_get_scaled(info, LTC3350_REG_CAP_OV_LVL, 1835, &val->intval); + default: + return -EINVAL; + } +} + +static int ltc3350_capacitor_set_property(struct power_supply *psy, enum power_supply_property psp, + const union power_supply_propval *val) +{ + struct ltc3350_info *info = power_supply_get_drvdata(psy); + + switch (psp) { + case POWER_SUPPLY_PROP_VOLTAGE_MIN: + return ltc3350_set_scaled(info, LTC3350_REG_VCAP_UV_LVL, 14760, val->intval); + case POWER_SUPPLY_PROP_VOLTAGE_MAX: + return ltc3350_set_scaled(info, LTC3350_REG_VCAP_OV_LVL, 14760, val->intval); + case POWER_SUPPLY_PROP_CELL_VOLTAGE_MIN: + return ltc3350_set_scaled(info, LTC3350_REG_CAP_UV_LVL, 1835, val->intval); + case POWER_SUPPLY_PROP_CELL_VOLTAGE_MAX: + return ltc3350_set_scaled(info, LTC3350_REG_CAP_OV_LVL, 1835, val->intval); + default: + return -EINVAL; + } +} + +static enum power_supply_property ltc3350_capacitor_properties[] = { + POWER_SUPPLY_PROP_STATUS, + POWER_SUPPLY_PROP_TECHNOLOGY, + POWER_SUPPLY_PROP_VOLTAGE_NOW, + POWER_SUPPLY_PROP_VOLTAGE_MIN, + POWER_SUPPLY_PROP_VOLTAGE_MAX, + POWER_SUPPLY_PROP_CURRENT_NOW, + POWER_SUPPLY_PROP_NUMBER_OF_SERIAL_CELLS, + POWER_SUPPLY_PROP_CELL1_VOLTAGE_NOW, + POWER_SUPPLY_PROP_CELL2_VOLTAGE_NOW, + POWER_SUPPLY_PROP_CELL3_VOLTAGE_NOW, + POWER_SUPPLY_PROP_CELL4_VOLTAGE_NOW, + POWER_SUPPLY_PROP_CELL_VOLTAGE_MIN, + POWER_SUPPLY_PROP_CELL_VOLTAGE_MAX, +}; + +static const struct power_supply_desc ltc3350_capacitor_desc = { + .name = "ltc3350_capacitor", + .type = POWER_SUPPLY_TYPE_BATTERY, + .properties = ltc3350_capacitor_properties, + .num_properties = ARRAY_SIZE(ltc3350_capacitor_properties), + .get_property = ltc3350_capacitor_get_property, + .set_property = ltc3350_capacitor_set_property, + .property_is_writeable = ltc3350_property_is_writeable, +}; + +static char *ltc3350_supply_interface_capacitor[] = { "ltc3350_capacitor" }; + +static bool ltc3350_is_writeable_reg(struct device *dev, unsigned int reg) +{ + /* all registers up to this one are writeable */ + return reg < LTC3350_REG_NUM_CAPS; +} + +static bool ltc3350_is_volatile_reg(struct device *dev, unsigned int reg) +{ + /* read-only status registers and self-clearing register */ + return reg > LTC3350_REG_NUM_CAPS || reg == LTC3350_REG_CLR_ALARMS; +} + +static const struct regmap_config ltc3350_regmap_config = { + .reg_bits = 8, + .val_bits = 16, + .val_format_endian = REGMAP_ENDIAN_LITTLE, + .writeable_reg = ltc3350_is_writeable_reg, + .volatile_reg = ltc3350_is_volatile_reg, + .max_register = LTC3350_REG_MEAS_DTEMP, + .cache_type = REGCACHE_MAPLE, +}; + +static int ltc3350_probe(struct i2c_client *client) +{ + struct device *dev = &client->dev; + struct ltc3350_info *info; + struct power_supply_config ltc3350_config = {}; + int ret; + + info = devm_kzalloc(dev, sizeof(*info), GFP_KERNEL); + if (!info) + return -ENOMEM; + + info->client = client; + i2c_set_clientdata(client, info); + + info->regmap = devm_regmap_init_i2c(client, <c3350_regmap_config); + if (IS_ERR(info->regmap)) + return dev_err_probe(dev, PTR_ERR(info->regmap), + "Failed to initialize register map\n"); + + ret = device_property_read_u32(dev, "lltc,rsnsc-micro-ohms", + &info->rsnsc); + if (ret) + return dev_err_probe(dev, ret, "Missing lltc,rsnsc-micro-ohms property\n"); + + if (!info->rsnsc) + return -EINVAL; + + ret = device_property_read_u32(dev, "lltc,rsnsi-micro-ohms", + &info->rsnsi); + if (ret) + return dev_err_probe(dev, ret, "Missing lltc,rsnsi-micro-ohms property\n"); + + if (!info->rsnsi) + return -EINVAL; + + /* Clear and disable all interrupt sources*/ + ret = regmap_write(info->regmap, LTC3350_REG_CLR_ALARMS, 0xFFFF); + if (ret) + return dev_err_probe(dev, ret, "Failed to write configuration\n"); + + regmap_write(info->regmap, LTC3350_REG_MSK_ALARMS, 0); + regmap_write(info->regmap, LTC3350_REG_MSK_MON_STATUS, 0); + + ltc3350_config.fwnode = dev_fwnode(dev); + ltc3350_config.drv_data = info; + info->capacitor = devm_power_supply_register(dev, <c3350_capacitor_desc, <c3350_config); + if (IS_ERR(info->capacitor)) { + dev_err(dev, "Failed to register capacitor\n"); + return PTR_ERR(info->capacitor); + } + + ltc3350_config.supplied_to = ltc3350_supply_interface_capacitor; + ltc3350_config.num_supplicants = ARRAY_SIZE(ltc3350_supply_interface_capacitor); + ltc3350_config.attr_grp = ltc3350_attr_groups; + info->charger = devm_power_supply_register(dev, <c3350_desc, <c3350_config); + if (IS_ERR(info->charger)) { + dev_err(dev, "Failed to register charger\n"); + return PTR_ERR(info->charger); + } + + /* Enable interrupts on status changes */ + regmap_write(info->regmap, LTC3350_REG_MSK_MON_STATUS, + LTC3350_MON_POWER_FAILED | LTC3350_MON_POWER_RETURNED); + + return 0; +} + +static void ltc3350_alert(struct i2c_client *client, enum i2c_alert_protocol type, + unsigned int flag) +{ + struct ltc3350_info *info = i2c_get_clientdata(client); + + if (type != I2C_PROTOCOL_SMBUS_ALERT) + return; + + power_supply_changed(info->charger); +} + +static const struct i2c_device_id ltc3350_i2c_id_table[] = { + { "ltc3350", 0 }, + { }, +}; +MODULE_DEVICE_TABLE(i2c, ltc3350_i2c_id_table); + +static const struct of_device_id ltc3350_of_match[] = { + { .compatible = "lltc,ltc3350", }, + { }, +}; +MODULE_DEVICE_TABLE(of, ltc3350_of_match); + +static struct i2c_driver ltc3350_driver = { + .probe = ltc3350_probe, + .alert = ltc3350_alert, + .id_table = ltc3350_i2c_id_table, + .driver = { + .name = "ltc3350-charger", + .of_match_table = ltc3350_of_match, + }, +}; +module_i2c_driver(ltc3350_driver); + +MODULE_LICENSE("GPL"); +MODULE_AUTHOR("Mike Looijmans "); +MODULE_DESCRIPTION("LTC3350 charger driver");