diff mbox series

[2/3] power: supply: bq24190: Fix BQ24296 Vbus regulator support

Message ID 20241116203648.169100-2-hdegoede@redhat.com (mailing list archive)
State Handled Elsewhere, archived
Headers show
Series [1/3] dt-bindings: power: supply: bq24190: Add BQ24297 compatible | expand

Commit Message

Hans de Goede Nov. 16, 2024, 8:36 p.m. UTC
There are 2 issues with bq24296_set_otg_vbus():

1. When writing the OTG_CONFIG bit it uses POC_CHG_CONFIG_SHIFT which
   should be POC_OTG_CONFIG_SHIFT.

2. When turning the regulator off it never turns charging back on. Note
   this must be done through bq24190_charger_set_charge_type(), to ensure
   that the charge_type property value of none/trickle/fast is honored.

Resolve both issues to fix BQ24296 Vbus regulator support not working.

Fixes: b150a703b56f ("power: supply: bq24190_charger: Add support for BQ24296")
Signed-off-by: Hans de Goede <hdegoede@redhat.com>
---
 drivers/power/supply/bq24190_charger.c | 12 +++++++++---
 1 file changed, 9 insertions(+), 3 deletions(-)
diff mbox series

Patch

diff --git a/drivers/power/supply/bq24190_charger.c b/drivers/power/supply/bq24190_charger.c
index 0101aaca1a97..4881cbd0e672 100644
--- a/drivers/power/supply/bq24190_charger.c
+++ b/drivers/power/supply/bq24190_charger.c
@@ -567,6 +567,7 @@  static int bq24190_set_otg_vbus(struct bq24190_dev_info *bdi, bool enable)
 
 static int bq24296_set_otg_vbus(struct bq24190_dev_info *bdi, bool enable)
 {
+	union power_supply_propval val = { .intval = bdi->charge_type };
 	int ret;
 
 	ret = pm_runtime_resume_and_get(bdi->dev);
@@ -587,13 +588,18 @@  static int bq24296_set_otg_vbus(struct bq24190_dev_info *bdi, bool enable)
 
 		ret = bq24190_write_mask(bdi, BQ24190_REG_POC,
 					 BQ24296_REG_POC_OTG_CONFIG_MASK,
-					 BQ24296_REG_POC_CHG_CONFIG_SHIFT,
+					 BQ24296_REG_POC_OTG_CONFIG_SHIFT,
 					 BQ24296_REG_POC_OTG_CONFIG_OTG);
-	} else
+	} else {
 		ret = bq24190_write_mask(bdi, BQ24190_REG_POC,
 					 BQ24296_REG_POC_OTG_CONFIG_MASK,
-					 BQ24296_REG_POC_CHG_CONFIG_SHIFT,
+					 BQ24296_REG_POC_OTG_CONFIG_SHIFT,
 					 BQ24296_REG_POC_OTG_CONFIG_DISABLE);
+		if (ret < 0)
+			goto out;
+
+		ret = bq24190_charger_set_charge_type(bdi, &val);
+	}
 
 out:
 	pm_runtime_mark_last_busy(bdi->dev);