@@ -3364,8 +3364,11 @@ static void bnxt_re_process_res_ud_wc(struct bnxt_re_qp *qp,
struct ib_wc *wc,
struct bnxt_qplib_cqe *cqe)
{
+ struct bnxt_re_dev *rdev;
+ u16 vlan_id = 0;
u8 nw_type;
+ rdev = qp->rdev;
wc->opcode = IB_WC_RECV;
wc->status = __rc_to_ib_wc_status(cqe->status);
@@ -3377,9 +3380,12 @@ static void bnxt_re_process_res_ud_wc(struct bnxt_re_qp *qp,
memcpy(wc->smac, cqe->smac, ETH_ALEN);
wc->wc_flags |= IB_WC_WITH_SMAC;
if (cqe->flags & CQ_RES_UD_FLAGS_META_FORMAT_VLAN) {
- wc->vlan_id = (cqe->cfa_meta & 0xFFF);
- if (wc->vlan_id < 0x1000)
- wc->wc_flags |= IB_WC_WITH_VLAN;
+ vlan_id = (cqe->cfa_meta & 0xFFF);
+ }
+ /* Mark only if vlan_id is non zero */
+ if (vlan_id && bnxt_re_check_if_vlan_valid(rdev, vlan_id)) {
+ wc->vlan_id = vlan_id;
+ wc->wc_flags |= IB_WC_WITH_VLAN;
}
nw_type = (cqe->flags & CQ_RES_UD_FLAGS_ROCE_IP_VER_MASK) >>
CQ_RES_UD_FLAGS_ROCE_IP_VER_SFT;
When VF is configured with default vlan, HW strips the vlan from the packet and driver receives it in Rx completion. VLAN needs to be reported for UD work completion only if the vlan is configured on the host. Add a check for valid vlan in the UD receive path. Signed-off-by: Selvin Xavier <selvin.xavier@broadcom.com> --- drivers/infiniband/hw/bnxt_re/ib_verbs.c | 12 +++++++++--- 1 file changed, 9 insertions(+), 3 deletions(-)