diff mbox series

[v4,06/10] dt-bindings: timer: Add Sophgo sg2042 CLINT timer

Message ID 6e48cbe5e60f9ada2fd1fe58e803e127f1a678e5.1696433229.git.unicorn_wang@outlook.com (mailing list archive)
State Superseded
Headers show
Series Add Milk-V Pioneer RISC-V board support | expand

Checks

Context Check Description
conchuod/vmtest-for-next-PR fail PR summary
conchuod/patch-6-test-1 success .github/scripts/patches/build_rv32_defconfig.sh
conchuod/patch-6-test-2 success .github/scripts/patches/build_rv64_clang_allmodconfig.sh
conchuod/patch-6-test-3 success .github/scripts/patches/build_rv64_gcc_allmodconfig.sh
conchuod/patch-6-test-4 success .github/scripts/patches/build_rv64_nommu_k210_defconfig.sh
conchuod/patch-6-test-5 success .github/scripts/patches/build_rv64_nommu_virt_defconfig.sh
conchuod/patch-6-test-7 success .github/scripts/patches/dtb_warn_rv64.sh
conchuod/patch-6-test-8 success .github/scripts/patches/header_inline.sh
conchuod/patch-6-test-9 success .github/scripts/patches/kdoc.sh
conchuod/patch-6-test-10 success .github/scripts/patches/maintainers_patterns.sh
conchuod/patch-6-test-11 success .github/scripts/patches/module_param.sh
conchuod/patch-6-test-12 success .github/scripts/patches/verify_fixes.sh
conchuod/patch-6-test-13 success .github/scripts/patches/verify_signedoff.sh
conchuod/patch-6-test-6 warning .github/scripts/patches/checkpatch.sh

Commit Message

Chen Wang Oct. 4, 2023, 3:43 p.m. UTC
From: Inochi Amaoto <inochiama@outlook.com>

The clint of Sophgo's sg2042 is based off IP designed by T-HEAD, but
Sophgo changes this IP layout to fit its cpu design and is incompatible
with the standard sifive clint. The timer and ipi device are on the
different address, and can not be handled by the sifive,clint dt-bindings.

If we use the same compatible string for mswi and timer of the sg2042
clint like sifive,clint, the DT may be like this:

mswi: interrupt-controller@94000000 {
	compatible = "sophgo,sg2042-clint", "thead,c900-clint";
	interrupts-extended = <&cpu1intc 3>;
	reg = <0x94000000 0x00010000>;
};

timer: timer@ac000000 {
	compatible = "sophgo,sg2042-clint", "thead,c900-clint";
	interrupts-extended = <&cpu1intc 7>;
	reg = <0xac000000 0x00010000>;
};

Since the address of mswi and timer are different, it is hard to merge
them directly. So we need two DT nodes to handle both devices.
If we use this DT for SBI, it will parse the mswi device in the timer
initialization as the compatible string is the same, so will mswi.
As they are different devices, this incorrect initialization will cause
the system unusable.

There is a more robust ACLINT spec. can handle this situation, but
the spec. seems to be abandoned and will not be frozen in the predictable
future.

So it is not the time to add ACLINT spec in the kernel bindings. Instead,
using vendor bindings is more acceptable.

Add new vendor specific compatible strings to identify timer of sg2042
clint.

Signed-off-by: Inochi Amaoto <inochiama@outlook.com>
Signed-off-by: Chen Wang <unicorn_wang@outlook.com>
---
 .../timer/thead,c900-aclint-mtimer.yaml       | 43 +++++++++++++++++++
 1 file changed, 43 insertions(+)
 create mode 100644 Documentation/devicetree/bindings/timer/thead,c900-aclint-mtimer.yaml
diff mbox series

Patch

diff --git a/Documentation/devicetree/bindings/timer/thead,c900-aclint-mtimer.yaml b/Documentation/devicetree/bindings/timer/thead,c900-aclint-mtimer.yaml
new file mode 100644
index 000000000000..fbd235650e52
--- /dev/null
+++ b/Documentation/devicetree/bindings/timer/thead,c900-aclint-mtimer.yaml
@@ -0,0 +1,43 @@ 
+# SPDX-License-Identifier: (GPL-2.0-only OR BSD-2-Clause)
+%YAML 1.2
+---
+$id: http://devicetree.org/schemas/timer/thead,c900-aclint-mtimer.yaml#
+$schema: http://devicetree.org/meta-schemas/core.yaml#
+
+title: Sophgo CLINT Timer
+
+maintainers:
+  - Inochi Amaoto <inochiama@outlook.com>
+
+properties:
+  compatible:
+    items:
+      - enum:
+          - sophgo,sg2042-aclint-mtimer
+      - const: thead,c900-aclint-mtimer
+
+  reg:
+    maxItems: 1
+
+  interrupts-extended:
+    minItems: 1
+    maxItems: 4095
+
+additionalProperties: false
+
+required:
+  - compatible
+  - reg
+  - interrupts-extended
+
+examples:
+  - |
+    timer@ac000000 {
+      compatible = "sophgo,sg2042-aclint-mtimer", "thead,c900-aclint-mtimer";
+      interrupts-extended = <&cpu1intc 7>,
+                            <&cpu2intc 7>,
+                            <&cpu3intc 7>,
+                            <&cpu4intc 7>;
+      reg = <0xac000000 0x00010000>;
+    };
+...