@@ -104,6 +104,25 @@ Detailed correlation between sub-blocks and power line according to Exynos SoC:
|--- LCD0
|--- ISP
+- In case of Exynos5422, there are two power line as following:
+ VDD_MIF |--- DREX 0 (parent device, DRAM EXpress controller)
+ |--- DREX 1
+
+ VDD_INT |--- NoC_Core (parent device)
+ |--- G2D
+ |--- G3D
+ |--- DISP1
+ |--- NoC_WCORE
+ |--- GSCL
+ |--- MSCL
+ |--- ISP
+ |--- MFC
+ |--- GEN
+ |--- PERIS
+ |--- PERIC
+ |--- FSYS
+ |--- FSYS2
+
Example1:
Show the AXI buses of Exynos3250 SoC. Exynos3250 divides the buses to
power line (regulator). The MIF (Memory Interface) AXI bus is used to
This patch adds the detailed corrleation between sub-blocks and power line for Exynos5422. Signed-off-by: Chanwoo Choi <cw00.choi@samsung.com> --- .../devicetree/bindings/devfreq/exynos-bus.txt | 19 +++++++++++++++++++ 1 file changed, 19 insertions(+)