diff mbox series

[08/10] ARM: dts: Cygnus: Fix SP805 clocks

Message ID 20200828130602.42203-9-andre.przywara@arm.com (mailing list archive)
State Not Applicable
Headers show
Series dt-bindings: Convert SP805 to Json-schema (and fix users) | expand

Commit Message

Andre Przywara Aug. 28, 2020, 1:06 p.m. UTC
The SP805 DT binding requires two clocks to be specified, but the
Broadcom Cygnus DT currently only specifies one clock.

In practice, Linux would pick a clock named "apb_pclk" for the bus
clock, and the Linux and U-Boot SP805 driver would use the first clock
to derive the actual watchdog counter frequency.

Since currently both are the very same clock, we can just double the
clock reference, and add the correct clock-names, to match the binding.

Signed-off-by: Andre Przywara <andre.przywara@arm.com>
---
 arch/arm/boot/dts/bcm-cygnus.dtsi | 4 ++--
 1 file changed, 2 insertions(+), 2 deletions(-)

Comments

Ray Jui Aug. 28, 2020, 5:09 p.m. UTC | #1
On 8/28/2020 6:06 AM, Andre Przywara wrote:
> The SP805 DT binding requires two clocks to be specified, but the
> Broadcom Cygnus DT currently only specifies one clock.
> 
> In practice, Linux would pick a clock named "apb_pclk" for the bus
> clock, and the Linux and U-Boot SP805 driver would use the first clock
> to derive the actual watchdog counter frequency.
> 
> Since currently both are the very same clock, we can just double the
> clock reference, and add the correct clock-names, to match the binding.
> 
> Signed-off-by: Andre Przywara <andre.przywara@arm.com>
> ---
>  arch/arm/boot/dts/bcm-cygnus.dtsi | 4 ++--
>  1 file changed, 2 insertions(+), 2 deletions(-)
> 
> diff --git a/arch/arm/boot/dts/bcm-cygnus.dtsi b/arch/arm/boot/dts/bcm-cygnus.dtsi
> index 35bdd0969f0a..dacaef2c14ca 100644
> --- a/arch/arm/boot/dts/bcm-cygnus.dtsi
> +++ b/arch/arm/boot/dts/bcm-cygnus.dtsi
> @@ -234,8 +234,8 @@
>  			compatible = "arm,sp805" , "arm,primecell";
>  			reg = <0x18009000 0x1000>;
>  			interrupts = <GIC_SPI 91 IRQ_TYPE_LEVEL_HIGH>;
> -			clocks = <&axi81_clk>;
> -			clock-names = "apb_pclk";
> +			clocks = <&axi81_clk>, <&axi81_clk>;
> +			clock-names = "wdog_clk", "apb_pclk";
>  		};
>  
>  		gpio_ccm: gpio@1800a000 {
> 

Reviewed-by: Ray Jui <ray.jui@broadcom.com>
Florian Fainelli Aug. 28, 2020, 7:31 p.m. UTC | #2
On 8/28/20 6:06 AM, Andre Przywara wrote:
> The SP805 DT binding requires two clocks to be specified, but the
> Broadcom Cygnus DT currently only specifies one clock.
> 
> In practice, Linux would pick a clock named "apb_pclk" for the bus
> clock, and the Linux and U-Boot SP805 driver would use the first clock
> to derive the actual watchdog counter frequency.
> 
> Since currently both are the very same clock, we can just double the
> clock reference, and add the correct clock-names, to match the binding.
> 
> Signed-off-by: Andre Przywara <andre.przywara@arm.com>

Acked-by: Florian Fainelli <f.fainelli@gmail.com>
Florian Fainelli Aug. 31, 2020, 3:55 a.m. UTC | #3
On Fri, 28 Aug 2020 14:06:00 +0100, Andre Przywara <andre.przywara@arm.com> wrote:
> The SP805 DT binding requires two clocks to be specified, but the
> Broadcom Cygnus DT currently only specifies one clock.
> 
> In practice, Linux would pick a clock named "apb_pclk" for the bus
> clock, and the Linux and U-Boot SP805 driver would use the first clock
> to derive the actual watchdog counter frequency.
> 
> Since currently both are the very same clock, we can just double the
> clock reference, and add the correct clock-names, to match the binding.
> 
> Signed-off-by: Andre Przywara <andre.przywara@arm.com>
> ---

Applied to qspi-fixes, thanks!
--
Florian
Florian Fainelli Aug. 31, 2020, 3:59 a.m. UTC | #4
On 8/30/2020 8:55 PM, Florian Fainelli wrote:
> On Fri, 28 Aug 2020 14:06:00 +0100, Andre Przywara <andre.przywara@arm.com> wrote:
>> The SP805 DT binding requires two clocks to be specified, but the
>> Broadcom Cygnus DT currently only specifies one clock.
>>
>> In practice, Linux would pick a clock named "apb_pclk" for the bus
>> clock, and the Linux and U-Boot SP805 driver would use the first clock
>> to derive the actual watchdog counter frequency.
>>
>> Since currently both are the very same clock, we can just double the
>> clock reference, and add the correct clock-names, to match the binding.
>>
>> Signed-off-by: Andre Przywara <andre.przywara@arm.com>
>> ---
> 
> Applied to qspi-fixes, thanks!

Applied to devicetree/next actually, likewise for the next patch.
diff mbox series

Patch

diff --git a/arch/arm/boot/dts/bcm-cygnus.dtsi b/arch/arm/boot/dts/bcm-cygnus.dtsi
index 35bdd0969f0a..dacaef2c14ca 100644
--- a/arch/arm/boot/dts/bcm-cygnus.dtsi
+++ b/arch/arm/boot/dts/bcm-cygnus.dtsi
@@ -234,8 +234,8 @@ 
 			compatible = "arm,sp805" , "arm,primecell";
 			reg = <0x18009000 0x1000>;
 			interrupts = <GIC_SPI 91 IRQ_TYPE_LEVEL_HIGH>;
-			clocks = <&axi81_clk>;
-			clock-names = "apb_pclk";
+			clocks = <&axi81_clk>, <&axi81_clk>;
+			clock-names = "wdog_clk", "apb_pclk";
 		};
 
 		gpio_ccm: gpio@1800a000 {