diff mbox series

[net-next,v4,08/10] bridge: cfm: Netlink GET configuration Interface.

Message ID 20201009143530.2438738-9-henrik.bjoernlund@microchip.com (mailing list archive)
State Superseded
Delegated to: Netdev Maintainers
Headers show
Series net: bridge: cfm: Add support for Connectivity Fault Management(CFM) | expand

Commit Message

Henrik Bjoernlund Oct. 9, 2020, 2:35 p.m. UTC
This is the implementation of CFM netlink configuration
get information interface.

Add new nested netlink attributes. These attributes are used by the
user space to get configuration information.

GETLINK:
    Request filter RTEXT_FILTER_CFM_CONFIG:
    Indicating that CFM configuration information must be delivered.

    IFLA_BRIDGE_CFM:
        Points to the CFM information.

    IFLA_BRIDGE_CFM_MEP_CREATE_INFO:
        This indicate that MEP instance create parameters are following.
    IFLA_BRIDGE_CFM_MEP_CONFIG_INFO:
        This indicate that MEP instance config parameters are following.
    IFLA_BRIDGE_CFM_CC_CONFIG_INFO:
        This indicate that MEP instance CC functionality
        parameters are following.
    IFLA_BRIDGE_CFM_CC_RDI_INFO:
        This indicate that CC transmitted CCM PDU RDI
        parameters are following.
    IFLA_BRIDGE_CFM_CC_CCM_TX_INFO:
        This indicate that CC transmitted CCM PDU parameters are
        following.
    IFLA_BRIDGE_CFM_CC_PEER_MEP_INFO:
        This indicate that the added peer MEP IDs are following.

CFM nested attribute has the following attributes in next level.

GETLINK RTEXT_FILTER_CFM_CONFIG:
    IFLA_BRIDGE_CFM_MEP_CREATE_INSTANCE:
        The created MEP instance number.
        The type is u32.
    IFLA_BRIDGE_CFM_MEP_CREATE_DOMAIN:
        The created MEP domain.
        The type is u32 (br_cfm_domain).
        It must be BR_CFM_PORT.
        This means that CFM frames are transmitted and received
        directly on the port - untagged. Not in a VLAN.
    IFLA_BRIDGE_CFM_MEP_CREATE_DIRECTION:
        The created MEP direction.
        The type is u32 (br_cfm_mep_direction).
        It must be BR_CFM_MEP_DIRECTION_DOWN.
        This means that CFM frames are transmitted and received on
        the port. Not in the bridge.
    IFLA_BRIDGE_CFM_MEP_CREATE_IFINDEX:
        The created MEP residence port ifindex.
        The type is u32 (ifindex).

    IFLA_BRIDGE_CFM_MEP_DELETE_INSTANCE:
        The deleted MEP instance number.
        The type is u32.

    IFLA_BRIDGE_CFM_MEP_CONFIG_INSTANCE:
        The configured MEP instance number.
        The type is u32.
    IFLA_BRIDGE_CFM_MEP_CONFIG_UNICAST_MAC:
        The configured MEP unicast MAC address.
        The type is 6*u8 (array).
        This is used as SMAC in all transmitted CFM frames.
    IFLA_BRIDGE_CFM_MEP_CONFIG_MDLEVEL:
        The configured MEP unicast MD level.
        The type is u32.
        It must be in the range 1-7.
        No CFM frames are passing through this MEP on lower levels.
    IFLA_BRIDGE_CFM_MEP_CONFIG_MEPID:
        The configured MEP ID.
        The type is u32.
        It must be in the range 0-0x1FFF.
        This MEP ID is inserted in any transmitted CCM frame.

    IFLA_BRIDGE_CFM_CC_CONFIG_INSTANCE:
        The configured MEP instance number.
        The type is u32.
    IFLA_BRIDGE_CFM_CC_CONFIG_ENABLE:
        The Continuity Check (CC) functionality is enabled or disabled.
        The type is u32 (bool).
    IFLA_BRIDGE_CFM_CC_CONFIG_EXP_INTERVAL:
        The CC expected receive interval of CCM frames.
        The type is u32 (br_cfm_ccm_interval).
        This is also the transmission interval of CCM frames when enabled.
    IFLA_BRIDGE_CFM_CC_CONFIG_EXP_MAID:
        The CC expected receive MAID in CCM frames.
        The type is CFM_MAID_LENGTH*u8.
        This is MAID is also inserted in transmitted CCM frames.

    IFLA_BRIDGE_CFM_CC_PEER_MEP_INSTANCE:
        The configured MEP instance number.
        The type is u32.
    IFLA_BRIDGE_CFM_CC_PEER_MEPID:
        The CC Peer MEP ID added.
        The type is u32.
        When a Peer MEP ID is added and CC is enabled it is expected to
        receive CCM frames from that Peer MEP.

    IFLA_BRIDGE_CFM_CC_RDI_INSTANCE:
        The configured MEP instance number.
        The type is u32.
    IFLA_BRIDGE_CFM_CC_RDI_RDI:
        The RDI that is inserted in transmitted CCM PDU.
        The type is u32 (bool).

    IFLA_BRIDGE_CFM_CC_CCM_TX_INSTANCE:
        The configured MEP instance number.
        The type is u32.
    IFLA_BRIDGE_CFM_CC_CCM_TX_DMAC:
        The transmitted CCM frame destination MAC address.
        The type is 6*u8 (array).
        This is used as DMAC in all transmitted CFM frames.
    IFLA_BRIDGE_CFM_CC_CCM_TX_SEQ_NO_UPDATE:
        The transmitted CCM frame update (increment) of sequence
        number is enabled or disabled.
        The type is u32 (bool).
    IFLA_BRIDGE_CFM_CC_CCM_TX_PERIOD:
        The period of time where CCM frame are transmitted.
        The type is u32.
        The time is given in seconds. SETLINK IFLA_BRIDGE_CFM_CC_CCM_TX
        must be done before timeout to keep transmission alive.
        When period is zero any ongoing CCM frame transmission
        will be stopped.
    IFLA_BRIDGE_CFM_CC_CCM_TX_IF_TLV:
        The transmitted CCM frame update with Interface Status TLV
        is enabled or disabled.
        The type is u32 (bool).
    IFLA_BRIDGE_CFM_CC_CCM_TX_IF_TLV_VALUE:
        The transmitted Interface Status TLV value field.
        The type is u8.
    IFLA_BRIDGE_CFM_CC_CCM_TX_PORT_TLV:
        The transmitted CCM frame update with Port Status TLV is enabled
        or disabled.
        The type is u32 (bool).
    IFLA_BRIDGE_CFM_CC_CCM_TX_PORT_TLV_VALUE:
        The transmitted Port Status TLV value field.
        The type is u8.

Signed-off-by: Henrik Bjoernlund  <henrik.bjoernlund@microchip.com>
Reviewed-by: Horatiu Vultur  <horatiu.vultur@microchip.com>
---
 include/uapi/linux/if_bridge.h |   6 ++
 net/bridge/br_cfm_netlink.c    | 161 +++++++++++++++++++++++++++++++++
 net/bridge/br_netlink.c        |  29 +++++-
 net/bridge/br_private.h        |   6 ++
 4 files changed, 200 insertions(+), 2 deletions(-)

Comments

Nikolay Aleksandrov Oct. 9, 2020, 9:56 p.m. UTC | #1
On Fri, 2020-10-09 at 14:35 +0000, Henrik Bjoernlund wrote:
> This is the implementation of CFM netlink configuration
> get information interface.
> 
> Add new nested netlink attributes. These attributes are used by the
> user space to get configuration information.
> 
> GETLINK:
>     Request filter RTEXT_FILTER_CFM_CONFIG:
>     Indicating that CFM configuration information must be delivered.
> 
>     IFLA_BRIDGE_CFM:
>         Points to the CFM information.
> 
>     IFLA_BRIDGE_CFM_MEP_CREATE_INFO:
>         This indicate that MEP instance create parameters are following.
>     IFLA_BRIDGE_CFM_MEP_CONFIG_INFO:
>         This indicate that MEP instance config parameters are following.
>     IFLA_BRIDGE_CFM_CC_CONFIG_INFO:
>         This indicate that MEP instance CC functionality
>         parameters are following.
>     IFLA_BRIDGE_CFM_CC_RDI_INFO:
>         This indicate that CC transmitted CCM PDU RDI
>         parameters are following.
>     IFLA_BRIDGE_CFM_CC_CCM_TX_INFO:
>         This indicate that CC transmitted CCM PDU parameters are
>         following.
>     IFLA_BRIDGE_CFM_CC_PEER_MEP_INFO:
>         This indicate that the added peer MEP IDs are following.
> 
> CFM nested attribute has the following attributes in next level.
> 
> GETLINK RTEXT_FILTER_CFM_CONFIG:
>     IFLA_BRIDGE_CFM_MEP_CREATE_INSTANCE:
>         The created MEP instance number.
>         The type is u32.
>     IFLA_BRIDGE_CFM_MEP_CREATE_DOMAIN:
>         The created MEP domain.
>         The type is u32 (br_cfm_domain).
>         It must be BR_CFM_PORT.
>         This means that CFM frames are transmitted and received
>         directly on the port - untagged. Not in a VLAN.
>     IFLA_BRIDGE_CFM_MEP_CREATE_DIRECTION:
>         The created MEP direction.
>         The type is u32 (br_cfm_mep_direction).
>         It must be BR_CFM_MEP_DIRECTION_DOWN.
>         This means that CFM frames are transmitted and received on
>         the port. Not in the bridge.
>     IFLA_BRIDGE_CFM_MEP_CREATE_IFINDEX:
>         The created MEP residence port ifindex.
>         The type is u32 (ifindex).
> 
>     IFLA_BRIDGE_CFM_MEP_DELETE_INSTANCE:
>         The deleted MEP instance number.
>         The type is u32.
> 
>     IFLA_BRIDGE_CFM_MEP_CONFIG_INSTANCE:
>         The configured MEP instance number.
>         The type is u32.
>     IFLA_BRIDGE_CFM_MEP_CONFIG_UNICAST_MAC:
>         The configured MEP unicast MAC address.
>         The type is 6*u8 (array).
>         This is used as SMAC in all transmitted CFM frames.
>     IFLA_BRIDGE_CFM_MEP_CONFIG_MDLEVEL:
>         The configured MEP unicast MD level.
>         The type is u32.
>         It must be in the range 1-7.
>         No CFM frames are passing through this MEP on lower levels.
>     IFLA_BRIDGE_CFM_MEP_CONFIG_MEPID:
>         The configured MEP ID.
>         The type is u32.
>         It must be in the range 0-0x1FFF.
>         This MEP ID is inserted in any transmitted CCM frame.
> 
>     IFLA_BRIDGE_CFM_CC_CONFIG_INSTANCE:
>         The configured MEP instance number.
>         The type is u32.
>     IFLA_BRIDGE_CFM_CC_CONFIG_ENABLE:
>         The Continuity Check (CC) functionality is enabled or disabled.
>         The type is u32 (bool).
>     IFLA_BRIDGE_CFM_CC_CONFIG_EXP_INTERVAL:
>         The CC expected receive interval of CCM frames.
>         The type is u32 (br_cfm_ccm_interval).
>         This is also the transmission interval of CCM frames when enabled.
>     IFLA_BRIDGE_CFM_CC_CONFIG_EXP_MAID:
>         The CC expected receive MAID in CCM frames.
>         The type is CFM_MAID_LENGTH*u8.
>         This is MAID is also inserted in transmitted CCM frames.
> 
>     IFLA_BRIDGE_CFM_CC_PEER_MEP_INSTANCE:
>         The configured MEP instance number.
>         The type is u32.
>     IFLA_BRIDGE_CFM_CC_PEER_MEPID:
>         The CC Peer MEP ID added.
>         The type is u32.
>         When a Peer MEP ID is added and CC is enabled it is expected to
>         receive CCM frames from that Peer MEP.
> 
>     IFLA_BRIDGE_CFM_CC_RDI_INSTANCE:
>         The configured MEP instance number.
>         The type is u32.
>     IFLA_BRIDGE_CFM_CC_RDI_RDI:
>         The RDI that is inserted in transmitted CCM PDU.
>         The type is u32 (bool).
> 
>     IFLA_BRIDGE_CFM_CC_CCM_TX_INSTANCE:
>         The configured MEP instance number.
>         The type is u32.
>     IFLA_BRIDGE_CFM_CC_CCM_TX_DMAC:
>         The transmitted CCM frame destination MAC address.
>         The type is 6*u8 (array).
>         This is used as DMAC in all transmitted CFM frames.
>     IFLA_BRIDGE_CFM_CC_CCM_TX_SEQ_NO_UPDATE:
>         The transmitted CCM frame update (increment) of sequence
>         number is enabled or disabled.
>         The type is u32 (bool).
>     IFLA_BRIDGE_CFM_CC_CCM_TX_PERIOD:
>         The period of time where CCM frame are transmitted.
>         The type is u32.
>         The time is given in seconds. SETLINK IFLA_BRIDGE_CFM_CC_CCM_TX
>         must be done before timeout to keep transmission alive.
>         When period is zero any ongoing CCM frame transmission
>         will be stopped.
>     IFLA_BRIDGE_CFM_CC_CCM_TX_IF_TLV:
>         The transmitted CCM frame update with Interface Status TLV
>         is enabled or disabled.
>         The type is u32 (bool).
>     IFLA_BRIDGE_CFM_CC_CCM_TX_IF_TLV_VALUE:
>         The transmitted Interface Status TLV value field.
>         The type is u8.
>     IFLA_BRIDGE_CFM_CC_CCM_TX_PORT_TLV:
>         The transmitted CCM frame update with Port Status TLV is enabled
>         or disabled.
>         The type is u32 (bool).
>     IFLA_BRIDGE_CFM_CC_CCM_TX_PORT_TLV_VALUE:
>         The transmitted Port Status TLV value field.
>         The type is u8.
> 
> Signed-off-by: Henrik Bjoernlund  <henrik.bjoernlund@microchip.com>
> Reviewed-by: Horatiu Vultur  <horatiu.vultur@microchip.com>
> ---
>  include/uapi/linux/if_bridge.h |   6 ++
>  net/bridge/br_cfm_netlink.c    | 161 +++++++++++++++++++++++++++++++++
>  net/bridge/br_netlink.c        |  29 +++++-
>  net/bridge/br_private.h        |   6 ++
>  4 files changed, 200 insertions(+), 2 deletions(-)
> 

Acked-by: Nikolay Aleksandrov <nikolay@nvidia.com>
Nikolay Aleksandrov Oct. 9, 2020, 9:59 p.m. UTC | #2
On Sat, 2020-10-10 at 00:56 +0300, Nikolay Aleksandrov wrote:
> On Fri, 2020-10-09 at 14:35 +0000, Henrik Bjoernlund wrote:
> > This is the implementation of CFM netlink configuration
> > get information interface.
> > 
> > Add new nested netlink attributes. These attributes are used by the
> > user space to get configuration information.
> > 
> > GETLINK:
> >     Request filter RTEXT_FILTER_CFM_CONFIG:
> >     Indicating that CFM configuration information must be delivered.
> > 
> >     IFLA_BRIDGE_CFM:
> >         Points to the CFM information.
> > 
> >     IFLA_BRIDGE_CFM_MEP_CREATE_INFO:
> >         This indicate that MEP instance create parameters are following.
> >     IFLA_BRIDGE_CFM_MEP_CONFIG_INFO:
> >         This indicate that MEP instance config parameters are following.
> >     IFLA_BRIDGE_CFM_CC_CONFIG_INFO:
> >         This indicate that MEP instance CC functionality
> >         parameters are following.
> >     IFLA_BRIDGE_CFM_CC_RDI_INFO:
> >         This indicate that CC transmitted CCM PDU RDI
> >         parameters are following.
> >     IFLA_BRIDGE_CFM_CC_CCM_TX_INFO:
> >         This indicate that CC transmitted CCM PDU parameters are
> >         following.
> >     IFLA_BRIDGE_CFM_CC_PEER_MEP_INFO:
> >         This indicate that the added peer MEP IDs are following.
> > 
> > CFM nested attribute has the following attributes in next level.
> > 
> > GETLINK RTEXT_FILTER_CFM_CONFIG:
> >     IFLA_BRIDGE_CFM_MEP_CREATE_INSTANCE:
> >         The created MEP instance number.
> >         The type is u32.
> >     IFLA_BRIDGE_CFM_MEP_CREATE_DOMAIN:
> >         The created MEP domain.
> >         The type is u32 (br_cfm_domain).
> >         It must be BR_CFM_PORT.
> >         This means that CFM frames are transmitted and received
> >         directly on the port - untagged. Not in a VLAN.
> >     IFLA_BRIDGE_CFM_MEP_CREATE_DIRECTION:
> >         The created MEP direction.
> >         The type is u32 (br_cfm_mep_direction).
> >         It must be BR_CFM_MEP_DIRECTION_DOWN.
> >         This means that CFM frames are transmitted and received on
> >         the port. Not in the bridge.
> >     IFLA_BRIDGE_CFM_MEP_CREATE_IFINDEX:
> >         The created MEP residence port ifindex.
> >         The type is u32 (ifindex).
> > 
> >     IFLA_BRIDGE_CFM_MEP_DELETE_INSTANCE:
> >         The deleted MEP instance number.
> >         The type is u32.
> > 
> >     IFLA_BRIDGE_CFM_MEP_CONFIG_INSTANCE:
> >         The configured MEP instance number.
> >         The type is u32.
> >     IFLA_BRIDGE_CFM_MEP_CONFIG_UNICAST_MAC:
> >         The configured MEP unicast MAC address.
> >         The type is 6*u8 (array).
> >         This is used as SMAC in all transmitted CFM frames.
> >     IFLA_BRIDGE_CFM_MEP_CONFIG_MDLEVEL:
> >         The configured MEP unicast MD level.
> >         The type is u32.
> >         It must be in the range 1-7.
> >         No CFM frames are passing through this MEP on lower levels.
> >     IFLA_BRIDGE_CFM_MEP_CONFIG_MEPID:
> >         The configured MEP ID.
> >         The type is u32.
> >         It must be in the range 0-0x1FFF.
> >         This MEP ID is inserted in any transmitted CCM frame.
> > 
> >     IFLA_BRIDGE_CFM_CC_CONFIG_INSTANCE:
> >         The configured MEP instance number.
> >         The type is u32.
> >     IFLA_BRIDGE_CFM_CC_CONFIG_ENABLE:
> >         The Continuity Check (CC) functionality is enabled or disabled.
> >         The type is u32 (bool).
> >     IFLA_BRIDGE_CFM_CC_CONFIG_EXP_INTERVAL:
> >         The CC expected receive interval of CCM frames.
> >         The type is u32 (br_cfm_ccm_interval).
> >         This is also the transmission interval of CCM frames when enabled.
> >     IFLA_BRIDGE_CFM_CC_CONFIG_EXP_MAID:
> >         The CC expected receive MAID in CCM frames.
> >         The type is CFM_MAID_LENGTH*u8.
> >         This is MAID is also inserted in transmitted CCM frames.
> > 
> >     IFLA_BRIDGE_CFM_CC_PEER_MEP_INSTANCE:
> >         The configured MEP instance number.
> >         The type is u32.
> >     IFLA_BRIDGE_CFM_CC_PEER_MEPID:
> >         The CC Peer MEP ID added.
> >         The type is u32.
> >         When a Peer MEP ID is added and CC is enabled it is expected to
> >         receive CCM frames from that Peer MEP.
> > 
> >     IFLA_BRIDGE_CFM_CC_RDI_INSTANCE:
> >         The configured MEP instance number.
> >         The type is u32.
> >     IFLA_BRIDGE_CFM_CC_RDI_RDI:
> >         The RDI that is inserted in transmitted CCM PDU.
> >         The type is u32 (bool).
> > 
> >     IFLA_BRIDGE_CFM_CC_CCM_TX_INSTANCE:
> >         The configured MEP instance number.
> >         The type is u32.
> >     IFLA_BRIDGE_CFM_CC_CCM_TX_DMAC:
> >         The transmitted CCM frame destination MAC address.
> >         The type is 6*u8 (array).
> >         This is used as DMAC in all transmitted CFM frames.
> >     IFLA_BRIDGE_CFM_CC_CCM_TX_SEQ_NO_UPDATE:
> >         The transmitted CCM frame update (increment) of sequence
> >         number is enabled or disabled.
> >         The type is u32 (bool).
> >     IFLA_BRIDGE_CFM_CC_CCM_TX_PERIOD:
> >         The period of time where CCM frame are transmitted.
> >         The type is u32.
> >         The time is given in seconds. SETLINK IFLA_BRIDGE_CFM_CC_CCM_TX
> >         must be done before timeout to keep transmission alive.
> >         When period is zero any ongoing CCM frame transmission
> >         will be stopped.
> >     IFLA_BRIDGE_CFM_CC_CCM_TX_IF_TLV:
> >         The transmitted CCM frame update with Interface Status TLV
> >         is enabled or disabled.
> >         The type is u32 (bool).
> >     IFLA_BRIDGE_CFM_CC_CCM_TX_IF_TLV_VALUE:
> >         The transmitted Interface Status TLV value field.
> >         The type is u8.
> >     IFLA_BRIDGE_CFM_CC_CCM_TX_PORT_TLV:
> >         The transmitted CCM frame update with Port Status TLV is enabled
> >         or disabled.
> >         The type is u32 (bool).
> >     IFLA_BRIDGE_CFM_CC_CCM_TX_PORT_TLV_VALUE:
> >         The transmitted Port Status TLV value field.
> >         The type is u8.
> > 
> > Signed-off-by: Henrik Bjoernlund  <henrik.bjoernlund@microchip.com>
> > Reviewed-by: Horatiu Vultur  <horatiu.vultur@microchip.com>
> > ---
> >  include/uapi/linux/if_bridge.h |   6 ++
> >  net/bridge/br_cfm_netlink.c    | 161 +++++++++++++++++++++++++++++++++
> >  net/bridge/br_netlink.c        |  29 +++++-
> >  net/bridge/br_private.h        |   6 ++
> >  4 files changed, 200 insertions(+), 2 deletions(-)
> > 
> 
> Acked-by: Nikolay Aleksandrov <nikolay@nvidia.com>
> 

I missed this until now, but the local variables need to
be arranged in reverse xmas tree (longest to shortest) in 
br_cfm_config_fill_info().
Henrik Bjoernlund Oct. 12, 2020, 1:10 p.m. UTC | #3
Thanks for the review. Comments below.

The 10/09/2020 21:59, Nikolay Aleksandrov wrote:
> EXTERNAL EMAIL: Do not click links or open attachments unless you know the content is safe
> 
> On Sat, 2020-10-10 at 00:56 +0300, Nikolay Aleksandrov wrote:
> > On Fri, 2020-10-09 at 14:35 +0000, Henrik Bjoernlund wrote:
> > > This is the implementation of CFM netlink configuration
> > > get information interface.
> > >
> > > Add new nested netlink attributes. These attributes are used by the
> > > user space to get configuration information.
> > >
> > > GETLINK:
> > >     Request filter RTEXT_FILTER_CFM_CONFIG:
> > >     Indicating that CFM configuration information must be delivered.
> > >
> > >     IFLA_BRIDGE_CFM:
> > >         Points to the CFM information.
> > >
> > >     IFLA_BRIDGE_CFM_MEP_CREATE_INFO:
> > >         This indicate that MEP instance create parameters are following.
> > >     IFLA_BRIDGE_CFM_MEP_CONFIG_INFO:
> > >         This indicate that MEP instance config parameters are following.
> > >     IFLA_BRIDGE_CFM_CC_CONFIG_INFO:
> > >         This indicate that MEP instance CC functionality
> > >         parameters are following.
> > >     IFLA_BRIDGE_CFM_CC_RDI_INFO:
> > >         This indicate that CC transmitted CCM PDU RDI
> > >         parameters are following.
> > >     IFLA_BRIDGE_CFM_CC_CCM_TX_INFO:
> > >         This indicate that CC transmitted CCM PDU parameters are
> > >         following.
> > >     IFLA_BRIDGE_CFM_CC_PEER_MEP_INFO:
> > >         This indicate that the added peer MEP IDs are following.
> > >
> > > CFM nested attribute has the following attributes in next level.
> > >
> > > GETLINK RTEXT_FILTER_CFM_CONFIG:
> > >     IFLA_BRIDGE_CFM_MEP_CREATE_INSTANCE:
> > >         The created MEP instance number.
> > >         The type is u32.
> > >     IFLA_BRIDGE_CFM_MEP_CREATE_DOMAIN:
> > >         The created MEP domain.
> > >         The type is u32 (br_cfm_domain).
> > >         It must be BR_CFM_PORT.
> > >         This means that CFM frames are transmitted and received
> > >         directly on the port - untagged. Not in a VLAN.
> > >     IFLA_BRIDGE_CFM_MEP_CREATE_DIRECTION:
> > >         The created MEP direction.
> > >         The type is u32 (br_cfm_mep_direction).
> > >         It must be BR_CFM_MEP_DIRECTION_DOWN.
> > >         This means that CFM frames are transmitted and received on
> > >         the port. Not in the bridge.
> > >     IFLA_BRIDGE_CFM_MEP_CREATE_IFINDEX:
> > >         The created MEP residence port ifindex.
> > >         The type is u32 (ifindex).
> > >
> > >     IFLA_BRIDGE_CFM_MEP_DELETE_INSTANCE:
> > >         The deleted MEP instance number.
> > >         The type is u32.
> > >
> > >     IFLA_BRIDGE_CFM_MEP_CONFIG_INSTANCE:
> > >         The configured MEP instance number.
> > >         The type is u32.
> > >     IFLA_BRIDGE_CFM_MEP_CONFIG_UNICAST_MAC:
> > >         The configured MEP unicast MAC address.
> > >         The type is 6*u8 (array).
> > >         This is used as SMAC in all transmitted CFM frames.
> > >     IFLA_BRIDGE_CFM_MEP_CONFIG_MDLEVEL:
> > >         The configured MEP unicast MD level.
> > >         The type is u32.
> > >         It must be in the range 1-7.
> > >         No CFM frames are passing through this MEP on lower levels.
> > >     IFLA_BRIDGE_CFM_MEP_CONFIG_MEPID:
> > >         The configured MEP ID.
> > >         The type is u32.
> > >         It must be in the range 0-0x1FFF.
> > >         This MEP ID is inserted in any transmitted CCM frame.
> > >
> > >     IFLA_BRIDGE_CFM_CC_CONFIG_INSTANCE:
> > >         The configured MEP instance number.
> > >         The type is u32.
> > >     IFLA_BRIDGE_CFM_CC_CONFIG_ENABLE:
> > >         The Continuity Check (CC) functionality is enabled or disabled.
> > >         The type is u32 (bool).
> > >     IFLA_BRIDGE_CFM_CC_CONFIG_EXP_INTERVAL:
> > >         The CC expected receive interval of CCM frames.
> > >         The type is u32 (br_cfm_ccm_interval).
> > >         This is also the transmission interval of CCM frames when enabled.
> > >     IFLA_BRIDGE_CFM_CC_CONFIG_EXP_MAID:
> > >         The CC expected receive MAID in CCM frames.
> > >         The type is CFM_MAID_LENGTH*u8.
> > >         This is MAID is also inserted in transmitted CCM frames.
> > >
> > >     IFLA_BRIDGE_CFM_CC_PEER_MEP_INSTANCE:
> > >         The configured MEP instance number.
> > >         The type is u32.
> > >     IFLA_BRIDGE_CFM_CC_PEER_MEPID:
> > >         The CC Peer MEP ID added.
> > >         The type is u32.
> > >         When a Peer MEP ID is added and CC is enabled it is expected to
> > >         receive CCM frames from that Peer MEP.
> > >
> > >     IFLA_BRIDGE_CFM_CC_RDI_INSTANCE:
> > >         The configured MEP instance number.
> > >         The type is u32.
> > >     IFLA_BRIDGE_CFM_CC_RDI_RDI:
> > >         The RDI that is inserted in transmitted CCM PDU.
> > >         The type is u32 (bool).
> > >
> > >     IFLA_BRIDGE_CFM_CC_CCM_TX_INSTANCE:
> > >         The configured MEP instance number.
> > >         The type is u32.
> > >     IFLA_BRIDGE_CFM_CC_CCM_TX_DMAC:
> > >         The transmitted CCM frame destination MAC address.
> > >         The type is 6*u8 (array).
> > >         This is used as DMAC in all transmitted CFM frames.
> > >     IFLA_BRIDGE_CFM_CC_CCM_TX_SEQ_NO_UPDATE:
> > >         The transmitted CCM frame update (increment) of sequence
> > >         number is enabled or disabled.
> > >         The type is u32 (bool).
> > >     IFLA_BRIDGE_CFM_CC_CCM_TX_PERIOD:
> > >         The period of time where CCM frame are transmitted.
> > >         The type is u32.
> > >         The time is given in seconds. SETLINK IFLA_BRIDGE_CFM_CC_CCM_TX
> > >         must be done before timeout to keep transmission alive.
> > >         When period is zero any ongoing CCM frame transmission
> > >         will be stopped.
> > >     IFLA_BRIDGE_CFM_CC_CCM_TX_IF_TLV:
> > >         The transmitted CCM frame update with Interface Status TLV
> > >         is enabled or disabled.
> > >         The type is u32 (bool).
> > >     IFLA_BRIDGE_CFM_CC_CCM_TX_IF_TLV_VALUE:
> > >         The transmitted Interface Status TLV value field.
> > >         The type is u8.
> > >     IFLA_BRIDGE_CFM_CC_CCM_TX_PORT_TLV:
> > >         The transmitted CCM frame update with Port Status TLV is enabled
> > >         or disabled.
> > >         The type is u32 (bool).
> > >     IFLA_BRIDGE_CFM_CC_CCM_TX_PORT_TLV_VALUE:
> > >         The transmitted Port Status TLV value field.
> > >         The type is u8.
> > >
> > > Signed-off-by: Henrik Bjoernlund  <henrik.bjoernlund@microchip.com>
> > > Reviewed-by: Horatiu Vultur  <horatiu.vultur@microchip.com>
> > > ---
> > >  include/uapi/linux/if_bridge.h |   6 ++
> > >  net/bridge/br_cfm_netlink.c    | 161 +++++++++++++++++++++++++++++++++
> > >  net/bridge/br_netlink.c        |  29 +++++-
> > >  net/bridge/br_private.h        |   6 ++
> > >  4 files changed, 200 insertions(+), 2 deletions(-)
> > >
> >
> > Acked-by: Nikolay Aleksandrov <nikolay@nvidia.com>
> >
> 
> I missed this until now, but the local variables need to
> be arranged in reverse xmas tree (longest to shortest) in
> br_cfm_config_fill_info().
> 
I changed this as requested.
>
Henrik Bjoernlund Oct. 12, 2020, 1:10 p.m. UTC | #4
Thanks for the review.

The 10/09/2020 21:56, Nikolay Aleksandrov wrote:
> EXTERNAL EMAIL: Do not click links or open attachments unless you know the content is safe
> 
> On Fri, 2020-10-09 at 14:35 +0000, Henrik Bjoernlund wrote:
> > This is the implementation of CFM netlink configuration
> > get information interface.
> >
> > Add new nested netlink attributes. These attributes are used by the
> > user space to get configuration information.
> >
> > GETLINK:
> >     Request filter RTEXT_FILTER_CFM_CONFIG:
> >     Indicating that CFM configuration information must be delivered.
> >
> >     IFLA_BRIDGE_CFM:
> >         Points to the CFM information.
> >
> >     IFLA_BRIDGE_CFM_MEP_CREATE_INFO:
> >         This indicate that MEP instance create parameters are following.
> >     IFLA_BRIDGE_CFM_MEP_CONFIG_INFO:
> >         This indicate that MEP instance config parameters are following.
> >     IFLA_BRIDGE_CFM_CC_CONFIG_INFO:
> >         This indicate that MEP instance CC functionality
> >         parameters are following.
> >     IFLA_BRIDGE_CFM_CC_RDI_INFO:
> >         This indicate that CC transmitted CCM PDU RDI
> >         parameters are following.
> >     IFLA_BRIDGE_CFM_CC_CCM_TX_INFO:
> >         This indicate that CC transmitted CCM PDU parameters are
> >         following.
> >     IFLA_BRIDGE_CFM_CC_PEER_MEP_INFO:
> >         This indicate that the added peer MEP IDs are following.
> >
> > CFM nested attribute has the following attributes in next level.
> >
> > GETLINK RTEXT_FILTER_CFM_CONFIG:
> >     IFLA_BRIDGE_CFM_MEP_CREATE_INSTANCE:
> >         The created MEP instance number.
> >         The type is u32.
> >     IFLA_BRIDGE_CFM_MEP_CREATE_DOMAIN:
> >         The created MEP domain.
> >         The type is u32 (br_cfm_domain).
> >         It must be BR_CFM_PORT.
> >         This means that CFM frames are transmitted and received
> >         directly on the port - untagged. Not in a VLAN.
> >     IFLA_BRIDGE_CFM_MEP_CREATE_DIRECTION:
> >         The created MEP direction.
> >         The type is u32 (br_cfm_mep_direction).
> >         It must be BR_CFM_MEP_DIRECTION_DOWN.
> >         This means that CFM frames are transmitted and received on
> >         the port. Not in the bridge.
> >     IFLA_BRIDGE_CFM_MEP_CREATE_IFINDEX:
> >         The created MEP residence port ifindex.
> >         The type is u32 (ifindex).
> >
> >     IFLA_BRIDGE_CFM_MEP_DELETE_INSTANCE:
> >         The deleted MEP instance number.
> >         The type is u32.
> >
> >     IFLA_BRIDGE_CFM_MEP_CONFIG_INSTANCE:
> >         The configured MEP instance number.
> >         The type is u32.
> >     IFLA_BRIDGE_CFM_MEP_CONFIG_UNICAST_MAC:
> >         The configured MEP unicast MAC address.
> >         The type is 6*u8 (array).
> >         This is used as SMAC in all transmitted CFM frames.
> >     IFLA_BRIDGE_CFM_MEP_CONFIG_MDLEVEL:
> >         The configured MEP unicast MD level.
> >         The type is u32.
> >         It must be in the range 1-7.
> >         No CFM frames are passing through this MEP on lower levels.
> >     IFLA_BRIDGE_CFM_MEP_CONFIG_MEPID:
> >         The configured MEP ID.
> >         The type is u32.
> >         It must be in the range 0-0x1FFF.
> >         This MEP ID is inserted in any transmitted CCM frame.
> >
> >     IFLA_BRIDGE_CFM_CC_CONFIG_INSTANCE:
> >         The configured MEP instance number.
> >         The type is u32.
> >     IFLA_BRIDGE_CFM_CC_CONFIG_ENABLE:
> >         The Continuity Check (CC) functionality is enabled or disabled.
> >         The type is u32 (bool).
> >     IFLA_BRIDGE_CFM_CC_CONFIG_EXP_INTERVAL:
> >         The CC expected receive interval of CCM frames.
> >         The type is u32 (br_cfm_ccm_interval).
> >         This is also the transmission interval of CCM frames when enabled.
> >     IFLA_BRIDGE_CFM_CC_CONFIG_EXP_MAID:
> >         The CC expected receive MAID in CCM frames.
> >         The type is CFM_MAID_LENGTH*u8.
> >         This is MAID is also inserted in transmitted CCM frames.
> >
> >     IFLA_BRIDGE_CFM_CC_PEER_MEP_INSTANCE:
> >         The configured MEP instance number.
> >         The type is u32.
> >     IFLA_BRIDGE_CFM_CC_PEER_MEPID:
> >         The CC Peer MEP ID added.
> >         The type is u32.
> >         When a Peer MEP ID is added and CC is enabled it is expected to
> >         receive CCM frames from that Peer MEP.
> >
> >     IFLA_BRIDGE_CFM_CC_RDI_INSTANCE:
> >         The configured MEP instance number.
> >         The type is u32.
> >     IFLA_BRIDGE_CFM_CC_RDI_RDI:
> >         The RDI that is inserted in transmitted CCM PDU.
> >         The type is u32 (bool).
> >
> >     IFLA_BRIDGE_CFM_CC_CCM_TX_INSTANCE:
> >         The configured MEP instance number.
> >         The type is u32.
> >     IFLA_BRIDGE_CFM_CC_CCM_TX_DMAC:
> >         The transmitted CCM frame destination MAC address.
> >         The type is 6*u8 (array).
> >         This is used as DMAC in all transmitted CFM frames.
> >     IFLA_BRIDGE_CFM_CC_CCM_TX_SEQ_NO_UPDATE:
> >         The transmitted CCM frame update (increment) of sequence
> >         number is enabled or disabled.
> >         The type is u32 (bool).
> >     IFLA_BRIDGE_CFM_CC_CCM_TX_PERIOD:
> >         The period of time where CCM frame are transmitted.
> >         The type is u32.
> >         The time is given in seconds. SETLINK IFLA_BRIDGE_CFM_CC_CCM_TX
> >         must be done before timeout to keep transmission alive.
> >         When period is zero any ongoing CCM frame transmission
> >         will be stopped.
> >     IFLA_BRIDGE_CFM_CC_CCM_TX_IF_TLV:
> >         The transmitted CCM frame update with Interface Status TLV
> >         is enabled or disabled.
> >         The type is u32 (bool).
> >     IFLA_BRIDGE_CFM_CC_CCM_TX_IF_TLV_VALUE:
> >         The transmitted Interface Status TLV value field.
> >         The type is u8.
> >     IFLA_BRIDGE_CFM_CC_CCM_TX_PORT_TLV:
> >         The transmitted CCM frame update with Port Status TLV is enabled
> >         or disabled.
> >         The type is u32 (bool).
> >     IFLA_BRIDGE_CFM_CC_CCM_TX_PORT_TLV_VALUE:
> >         The transmitted Port Status TLV value field.
> >         The type is u8.
> >
> > Signed-off-by: Henrik Bjoernlund  <henrik.bjoernlund@microchip.com>
> > Reviewed-by: Horatiu Vultur  <horatiu.vultur@microchip.com>
> > ---
> >  include/uapi/linux/if_bridge.h |   6 ++
> >  net/bridge/br_cfm_netlink.c    | 161 +++++++++++++++++++++++++++++++++
> >  net/bridge/br_netlink.c        |  29 +++++-
> >  net/bridge/br_private.h        |   6 ++
> >  4 files changed, 200 insertions(+), 2 deletions(-)
> >
> 
> Acked-by: Nikolay Aleksandrov <nikolay@nvidia.com>
>
diff mbox series

Patch

diff --git a/include/uapi/linux/if_bridge.h b/include/uapi/linux/if_bridge.h
index 94cc9444d749..b8b4491922d9 100644
--- a/include/uapi/linux/if_bridge.h
+++ b/include/uapi/linux/if_bridge.h
@@ -339,6 +339,12 @@  enum {
 	IFLA_BRIDGE_CFM_CC_PEER_MEP_REMOVE,
 	IFLA_BRIDGE_CFM_CC_RDI,
 	IFLA_BRIDGE_CFM_CC_CCM_TX,
+	IFLA_BRIDGE_CFM_MEP_CREATE_INFO,
+	IFLA_BRIDGE_CFM_MEP_CONFIG_INFO,
+	IFLA_BRIDGE_CFM_CC_CONFIG_INFO,
+	IFLA_BRIDGE_CFM_CC_RDI_INFO,
+	IFLA_BRIDGE_CFM_CC_CCM_TX_INFO,
+	IFLA_BRIDGE_CFM_CC_PEER_MEP_INFO,
 	__IFLA_BRIDGE_CFM_MAX,
 };
 
diff --git a/net/bridge/br_cfm_netlink.c b/net/bridge/br_cfm_netlink.c
index 0b32873a1241..952b6372874e 100644
--- a/net/bridge/br_cfm_netlink.c
+++ b/net/bridge/br_cfm_netlink.c
@@ -456,3 +456,164 @@  int br_cfm_parse(struct net_bridge *br, struct net_bridge_port *p,
 
 	return 0;
 }
+
+int br_cfm_config_fill_info(struct sk_buff *skb, struct net_bridge *br)
+{
+	struct nlattr *tb;
+	struct br_cfm_mep *mep;
+	struct br_cfm_peer_mep *peer_mep;
+
+	hlist_for_each_entry_rcu(mep, &br->mep_list, head) {
+		tb = nla_nest_start(skb, IFLA_BRIDGE_CFM_MEP_CREATE_INFO);
+		if (!tb)
+			goto nla_info_failure;
+
+		if (nla_put_u32(skb, IFLA_BRIDGE_CFM_MEP_CREATE_INSTANCE,
+				mep->instance))
+			goto nla_put_failure;
+
+		if (nla_put_u32(skb, IFLA_BRIDGE_CFM_MEP_CREATE_DOMAIN,
+				mep->create.domain))
+			goto nla_put_failure;
+
+		if (nla_put_u32(skb, IFLA_BRIDGE_CFM_MEP_CREATE_DIRECTION,
+				mep->create.direction))
+			goto nla_put_failure;
+
+		if (nla_put_u32(skb, IFLA_BRIDGE_CFM_MEP_CREATE_IFINDEX,
+				mep->create.ifindex))
+			goto nla_put_failure;
+
+		nla_nest_end(skb, tb);
+
+		tb = nla_nest_start(skb, IFLA_BRIDGE_CFM_MEP_CONFIG_INFO);
+
+		if (!tb)
+			goto nla_info_failure;
+
+		if (nla_put_u32(skb, IFLA_BRIDGE_CFM_MEP_CONFIG_INSTANCE,
+				mep->instance))
+			goto nla_put_failure;
+
+		if (nla_put(skb, IFLA_BRIDGE_CFM_MEP_CONFIG_UNICAST_MAC,
+			    sizeof(mep->config.unicast_mac.addr),
+			    mep->config.unicast_mac.addr))
+			goto nla_put_failure;
+
+		if (nla_put_u32(skb, IFLA_BRIDGE_CFM_MEP_CONFIG_MDLEVEL,
+				mep->config.mdlevel))
+			goto nla_put_failure;
+
+		if (nla_put_u32(skb, IFLA_BRIDGE_CFM_MEP_CONFIG_MEPID,
+				mep->config.mepid))
+			goto nla_put_failure;
+
+		nla_nest_end(skb, tb);
+
+		tb = nla_nest_start(skb, IFLA_BRIDGE_CFM_CC_CONFIG_INFO);
+
+		if (!tb)
+			goto nla_info_failure;
+
+		if (nla_put_u32(skb, IFLA_BRIDGE_CFM_CC_CONFIG_INSTANCE,
+				mep->instance))
+			goto nla_put_failure;
+
+		if (nla_put_u32(skb, IFLA_BRIDGE_CFM_CC_CONFIG_ENABLE,
+				mep->cc_config.enable))
+			goto nla_put_failure;
+
+		if (nla_put_u32(skb, IFLA_BRIDGE_CFM_CC_CONFIG_EXP_INTERVAL,
+				mep->cc_config.exp_interval))
+			goto nla_put_failure;
+
+		if (nla_put(skb, IFLA_BRIDGE_CFM_CC_CONFIG_EXP_MAID,
+			    sizeof(mep->cc_config.exp_maid.data),
+			    mep->cc_config.exp_maid.data))
+			goto nla_put_failure;
+
+		nla_nest_end(skb, tb);
+
+		tb = nla_nest_start(skb, IFLA_BRIDGE_CFM_CC_RDI_INFO);
+
+		if (!tb)
+			goto nla_info_failure;
+
+		if (nla_put_u32(skb, IFLA_BRIDGE_CFM_CC_RDI_INSTANCE,
+				mep->instance))
+			goto nla_put_failure;
+
+		if (nla_put_u32(skb, IFLA_BRIDGE_CFM_CC_RDI_RDI,
+				mep->rdi))
+			goto nla_put_failure;
+
+		nla_nest_end(skb, tb);
+
+		tb = nla_nest_start(skb, IFLA_BRIDGE_CFM_CC_CCM_TX_INFO);
+
+		if (!tb)
+			goto nla_info_failure;
+
+		if (nla_put_u32(skb, IFLA_BRIDGE_CFM_CC_CCM_TX_INSTANCE,
+				mep->instance))
+			goto nla_put_failure;
+
+		if (nla_put(skb, IFLA_BRIDGE_CFM_CC_CCM_TX_DMAC,
+			    sizeof(mep->cc_ccm_tx_info.dmac),
+			    mep->cc_ccm_tx_info.dmac.addr))
+			goto nla_put_failure;
+
+		if (nla_put_u32(skb, IFLA_BRIDGE_CFM_CC_CCM_TX_SEQ_NO_UPDATE,
+				mep->cc_ccm_tx_info.seq_no_update))
+			goto nla_put_failure;
+
+		if (nla_put_u32(skb, IFLA_BRIDGE_CFM_CC_CCM_TX_PERIOD,
+				mep->cc_ccm_tx_info.period))
+			goto nla_put_failure;
+
+		if (nla_put_u32(skb, IFLA_BRIDGE_CFM_CC_CCM_TX_IF_TLV,
+				mep->cc_ccm_tx_info.if_tlv))
+			goto nla_put_failure;
+
+		if (nla_put_u8(skb, IFLA_BRIDGE_CFM_CC_CCM_TX_IF_TLV_VALUE,
+			       mep->cc_ccm_tx_info.if_tlv_value))
+			goto nla_put_failure;
+
+		if (nla_put_u32(skb, IFLA_BRIDGE_CFM_CC_CCM_TX_PORT_TLV,
+				mep->cc_ccm_tx_info.port_tlv))
+			goto nla_put_failure;
+
+		if (nla_put_u8(skb, IFLA_BRIDGE_CFM_CC_CCM_TX_PORT_TLV_VALUE,
+			       mep->cc_ccm_tx_info.port_tlv_value))
+			goto nla_put_failure;
+
+		nla_nest_end(skb, tb);
+
+		hlist_for_each_entry_rcu(peer_mep, &mep->peer_mep_list, head) {
+			tb = nla_nest_start(skb,
+					    IFLA_BRIDGE_CFM_CC_PEER_MEP_INFO);
+
+			if (!tb)
+				goto nla_info_failure;
+
+			if (nla_put_u32(skb,
+					IFLA_BRIDGE_CFM_CC_PEER_MEP_INSTANCE,
+					mep->instance))
+				goto nla_put_failure;
+
+			if (nla_put_u32(skb, IFLA_BRIDGE_CFM_CC_PEER_MEPID,
+					peer_mep->mepid))
+				goto nla_put_failure;
+
+			nla_nest_end(skb, tb);
+		}
+	}
+
+	return 0;
+
+nla_put_failure:
+	nla_nest_cancel(skb, tb);
+
+nla_info_failure:
+	return -EMSGSIZE;
+}
diff --git a/net/bridge/br_netlink.c b/net/bridge/br_netlink.c
index 431ee2b06dc1..69bfe165ff7f 100644
--- a/net/bridge/br_netlink.c
+++ b/net/bridge/br_netlink.c
@@ -16,6 +16,7 @@ 
 
 #include "br_private.h"
 #include "br_private_stp.h"
+#include "br_private_cfm.h"
 #include "br_private_tunnel.h"
 
 static int __get_num_vlan_infos(struct net_bridge_vlan_group *vg,
@@ -426,7 +427,8 @@  static int br_fill_ifinfo(struct sk_buff *skb,
 
 	if (filter_mask & (RTEXT_FILTER_BRVLAN |
 			   RTEXT_FILTER_BRVLAN_COMPRESSED |
-			   RTEXT_FILTER_MRP)) {
+			   RTEXT_FILTER_MRP |
+			   RTEXT_FILTER_CFM_CONFIG)) {
 		af = nla_nest_start_noflag(skb, IFLA_AF_SPEC);
 		if (!af)
 			goto nla_put_failure;
@@ -475,6 +477,28 @@  static int br_fill_ifinfo(struct sk_buff *skb,
 			goto nla_put_failure;
 	}
 
+	if (filter_mask & RTEXT_FILTER_CFM_CONFIG) {
+		struct nlattr *cfm_nest = NULL;
+		int err;
+
+		if (!br_cfm_created(br) || port)
+			goto done;
+
+		cfm_nest = nla_nest_start(skb, IFLA_BRIDGE_CFM);
+		if (!cfm_nest)
+			goto nla_put_failure;
+
+		if (filter_mask & RTEXT_FILTER_CFM_CONFIG) {
+			rcu_read_lock();
+			err = br_cfm_config_fill_info(skb, br);
+			rcu_read_unlock();
+			if (err)
+				goto nla_put_failure;
+		}
+
+		nla_nest_end(skb, cfm_nest);
+	}
+
 done:
 	if (af)
 		nla_nest_end(skb, af);
@@ -538,7 +562,8 @@  int br_getlink(struct sk_buff *skb, u32 pid, u32 seq,
 
 	if (!port && !(filter_mask & RTEXT_FILTER_BRVLAN) &&
 	    !(filter_mask & RTEXT_FILTER_BRVLAN_COMPRESSED) &&
-	    !(filter_mask & RTEXT_FILTER_MRP))
+	    !(filter_mask & RTEXT_FILTER_MRP) &&
+	    !(filter_mask & RTEXT_FILTER_CFM_CONFIG))
 		return 0;
 
 	return br_fill_ifinfo(skb, port, pid, seq, RTM_NEWLINK, nlflags,
diff --git a/net/bridge/br_private.h b/net/bridge/br_private.h
index 397d098dd694..7bfd7c09b01a 100644
--- a/net/bridge/br_private.h
+++ b/net/bridge/br_private.h
@@ -1466,6 +1466,7 @@  int br_cfm_parse(struct net_bridge *br, struct net_bridge_port *p,
 		 struct nlattr *attr, int cmd, struct netlink_ext_ack *extack);
 bool br_cfm_created(struct net_bridge *br);
 void br_cfm_port_del(struct net_bridge *br, struct net_bridge_port *p);
+int br_cfm_config_fill_info(struct sk_buff *skb, struct net_bridge *br);
 #else
 static inline int br_cfm_parse(struct net_bridge *br, struct net_bridge_port *p,
 			       struct nlattr *attr, int cmd,
@@ -1483,6 +1484,11 @@  static inline void br_cfm_port_del(struct net_bridge *br,
 				   struct net_bridge_port *p)
 {
 }
+
+static inline int br_cfm_config_fill_info(struct sk_buff *skb, struct net_bridge *br)
+{
+	return -EOPNOTSUPP;
+}
 #endif
 
 /* br_netlink.c */