Alexandru Ardelean Nov. 3, 2020, 7:44 a.m. UTC
When the PHY powers up, the diagnostics clock isn't enabled (bit 2 in
register PHY_CTRL_1 (0x0012)).
Also, the PHY is not in standby mode, so bit 13 in PHY_CTRL_3 (0x0017) is
always set at power up.

The standby mode and the diagnostics clock are both meant to be for the
cable diagnostics feature of the PHY (in phylib this would be equivalent to
the cable-test support), and for the frame-generator feature of the PHY.

In standby mode, the PHY doesn't negotiate links or manage links.

To use the cable diagnostics/test (or frame-generator), the PHY must be
first set in standby mode, so that the link operation doesn't interfere.
Then, the diagnostics clock must be enabled.

For the cable-test feature, when the operation finishes, the PHY goes into
PHY_UP state, and the config_aneg hook is called.

For the ADIN PHY, we need to make sure that during autonegotiation
configuration/setup the PHY is removed from standby mode and the
diagnostics clock is disabled, so that normal operation is resumed.

This change does that by moving the set of the ADIN1300_LINKING_EN bit (2)
in the config_aneg (to disable standby mode).
Previously, this was set in the downshift setup, because the downshift
retry value and the ADIN1300_LINKING_EN are in the same register.

And the ADIN1300_DIAG_CLK_EN bit (13) is cleared, to disable the
diagnostics clock.

Reviewed-by: Andrew Lunn <andrew@lunn.ch>
Signed-off-by: Alexandru Ardelean <alexandru.ardelean@analog.com>
---

This is a re-send of:
 https://lore.kernel.org/netdev/20201022074551.11520-1-alexandru.ardelean@analog.com/

Added 'Reviewed-by: Andrew Lunn <andrew@lunn.ch>' to both patches.

 drivers/net/phy/adin.c | 12 ++++++++++--
 1 file changed, 10 insertions(+), 2 deletions(-)

Comments

Jakub Kicinski Nov. 5, 2020, 1:06 a.m. UTC | #1
On Tue, 3 Nov 2020 09:44:35 +0200 Alexandru Ardelean wrote:
> When the PHY powers up, the diagnostics clock isn't enabled (bit 2 in
> register PHY_CTRL_1 (0x0012)).
> Also, the PHY is not in standby mode, so bit 13 in PHY_CTRL_3 (0x0017) is
> always set at power up.
> 
> The standby mode and the diagnostics clock are both meant to be for the
> cable diagnostics feature of the PHY (in phylib this would be equivalent to
> the cable-test support), and for the frame-generator feature of the PHY.
> 
> In standby mode, the PHY doesn't negotiate links or manage links.
> 
> To use the cable diagnostics/test (or frame-generator), the PHY must be
> first set in standby mode, so that the link operation doesn't interfere.
> Then, the diagnostics clock must be enabled.
> 
> For the cable-test feature, when the operation finishes, the PHY goes into
> PHY_UP state, and the config_aneg hook is called.
> 
> For the ADIN PHY, we need to make sure that during autonegotiation
> configuration/setup the PHY is removed from standby mode and the
> diagnostics clock is disabled, so that normal operation is resumed.
> 
> This change does that by moving the set of the ADIN1300_LINKING_EN bit (2)
> in the config_aneg (to disable standby mode).
> Previously, this was set in the downshift setup, because the downshift
> retry value and the ADIN1300_LINKING_EN are in the same register.
> 
> And the ADIN1300_DIAG_CLK_EN bit (13) is cleared, to disable the
> diagnostics clock.
> 
> Reviewed-by: Andrew Lunn <andrew@lunn.ch>
> Signed-off-by: Alexandru Ardelean <alexandru.ardelean@analog.com>

Applied both, thanks.
diff mbox series

Patch

diff --git a/drivers/net/phy/adin.c b/drivers/net/phy/adin.c
index 5bc3926c52f0..619d36685b5d 100644
--- a/drivers/net/phy/adin.c
+++ b/drivers/net/phy/adin.c
@@ -23,6 +23,7 @@ 
 #define ADIN1300_PHY_CTRL1			0x0012
 #define   ADIN1300_AUTO_MDI_EN			BIT(10)
 #define   ADIN1300_MAN_MDIX_EN			BIT(9)
+#define   ADIN1300_DIAG_CLK_EN			BIT(2)
 
 #define ADIN1300_RX_ERR_CNT			0x0014
 
@@ -326,10 +327,9 @@  static int adin_set_downshift(struct phy_device *phydev, u8 cnt)
 		return -E2BIG;
 
 	val = FIELD_PREP(ADIN1300_DOWNSPEED_RETRIES_MSK, cnt);
-	val |= ADIN1300_LINKING_EN;
 
 	rc = phy_modify(phydev, ADIN1300_PHY_CTRL3,
-			ADIN1300_LINKING_EN | ADIN1300_DOWNSPEED_RETRIES_MSK,
+			ADIN1300_DOWNSPEED_RETRIES_MSK,
 			val);
 	if (rc < 0)
 		return rc;
@@ -560,6 +560,14 @@  static int adin_config_aneg(struct phy_device *phydev)
 {
 	int ret;
 
+	ret = phy_clear_bits(phydev, ADIN1300_PHY_CTRL1, ADIN1300_DIAG_CLK_EN);
+	if (ret < 0)
+		return ret;
+
+	ret = phy_set_bits(phydev, ADIN1300_PHY_CTRL3, ADIN1300_LINKING_EN);
+	if (ret < 0)
+		return ret;
+
 	ret = adin_config_mdix(phydev);
 	if (ret)
 		return ret;