Message ID | 20230331-topic-oxnas-upstream-remove-v1-6-5bd58fd1dd1f@linaro.org (mailing list archive) |
---|---|
State | RFC |
Headers | show |
Series | ARM: oxnas support removal | expand |
Context | Check | Description |
---|---|---|
netdev/tree_selection | success | Guessing tree name failed - patch did not apply |
On 31/03/2023 10:34, Neil Armstrong wrote: > Due to lack of maintainance and stall of development for a few years now, > and since no new features will ever be added upstream, remove the > OX810 and OX820 clock bindings. > > Signed-off-by: Neil Armstrong <neil.armstrong@linaro.org> > --- Acked-by: Krzysztof Kozlowski <krzysztof.kozlowski@linaro.org> Best regards, Krzysztof
On Fri, Mar 31, 2023 at 10:34:44AM +0200, Neil Armstrong wrote: > Due to lack of maintainance and stall of development for a few years now, I can't spell it either, but checkpatch tells me it is: maintenance > and since no new features will ever be added upstream, remove the > OX810 and OX820 clock bindings. > > Signed-off-by: Neil Armstrong <neil.armstrong@linaro.org> > --- > .../devicetree/bindings/clock/oxnas,stdclk.txt | 28 ---------------------- > 1 file changed, 28 deletions(-) Always great to see fewer bindings. Rob
diff --git a/Documentation/devicetree/bindings/clock/oxnas,stdclk.txt b/Documentation/devicetree/bindings/clock/oxnas,stdclk.txt deleted file mode 100644 index b652f3fb7796..000000000000 --- a/Documentation/devicetree/bindings/clock/oxnas,stdclk.txt +++ /dev/null @@ -1,28 +0,0 @@ -Oxford Semiconductor OXNAS SoC Family Standard Clocks -================================================ - -Please also refer to clock-bindings.txt in this directory for common clock -bindings usage. - -Required properties: -- compatible: For OX810SE, should be "oxsemi,ox810se-stdclk" - For OX820, should be "oxsemi,ox820-stdclk" -- #clock-cells: 1, see below - -Parent node should have the following properties : -- compatible: For OX810SE, should be - "oxsemi,ox810se-sys-ctrl", "syscon", "simple-mfd" - For OX820, should be - "oxsemi,ox820-sys-ctrl", "syscon", "simple-mfd" - -example: - -sys: sys-ctrl@000000 { - compatible = "oxsemi,ox810se-sys-ctrl", "syscon", "simple-mfd"; - reg = <0x000000 0x100000>; - - stdclk: stdclk { - compatible = "oxsemi,ox810se-stdclk"; - #clock-cells = <1>; - }; -};
Due to lack of maintainance and stall of development for a few years now, and since no new features will ever be added upstream, remove the OX810 and OX820 clock bindings. Signed-off-by: Neil Armstrong <neil.armstrong@linaro.org> --- .../devicetree/bindings/clock/oxnas,stdclk.txt | 28 ---------------------- 1 file changed, 28 deletions(-)