diff mbox series

[v5,06/32] target/ppc/mmu_common.c: Introduce mmu6xx_get_physical_address()

Message ID 68484f16af6b4e222c83bb1fbd0ff7ac39b6d4bb.1715285340.git.balaton@eik.bme.hu (mailing list archive)
State New, archived
Headers show
Series Misc PPC exception and BookE MMU clean ups | expand

Commit Message

BALATON Zoltan May 9, 2024, 8:25 p.m. UTC
Repurpose get_segment_6xx_tlb() to do the whole address translation
for POWERPC_MMU_SOFT_6xx MMU model by moving the BAT check there and
renaming it to match other similar functions. These are only called
once together so no need to keep these separate functions and
combining them simplifies the caller allowing further restructuring.

Signed-off-by: BALATON Zoltan <balaton@eik.bme.hu>
Reviewed-by: Nicholas Piggin <npiggin@gmail.com>
---
 target/ppc/mmu_common.c | 26 ++++++++++++--------------
 1 file changed, 12 insertions(+), 14 deletions(-)
diff mbox series

Patch

diff --git a/target/ppc/mmu_common.c b/target/ppc/mmu_common.c
index 3391df61cb..b7c07cf515 100644
--- a/target/ppc/mmu_common.c
+++ b/target/ppc/mmu_common.c
@@ -360,19 +360,23 @@  static int get_bat_6xx_tlb(CPUPPCState *env, mmu_ctx_t *ctx,
     return ret;
 }
 
-/* Perform segment based translation */
-static int get_segment_6xx_tlb(CPUPPCState *env, mmu_ctx_t *ctx,
-                               target_ulong eaddr, MMUAccessType access_type,
-                               int type)
+static int mmu6xx_get_physical_address(CPUPPCState *env, mmu_ctx_t *ctx,
+                                       target_ulong eaddr,
+                                       MMUAccessType access_type, int type)
 {
     PowerPCCPU *cpu = env_archcpu(env);
     hwaddr hash;
-    target_ulong vsid;
+    target_ulong vsid, sr, pgidx;
     int ds, target_page_bits;
     bool pr;
     int ret;
-    target_ulong sr, pgidx;
 
+    /* First try to find a BAT entry if there are any */
+    if (env->nb_BATs && get_bat_6xx_tlb(env, ctx, eaddr, access_type) == 0) {
+        return 0;
+    }
+
+    /* Perform segment based translation when no BATs matched */
     pr = FIELD_EX64(env->msr, MSR, PR);
     ctx->eaddr = eaddr;
 
@@ -1194,14 +1198,8 @@  int get_physical_address_wtlb(CPUPPCState *env, mmu_ctx_t *ctx,
         if (real_mode) {
             ret = check_physical(env, ctx, eaddr, access_type);
         } else {
-            /* Try to find a BAT */
-            if (env->nb_BATs != 0) {
-                ret = get_bat_6xx_tlb(env, ctx, eaddr, access_type);
-            }
-            if (ret < 0) {
-                /* We didn't match any BAT entry or don't have BATs */
-                ret = get_segment_6xx_tlb(env, ctx, eaddr, access_type, type);
-            }
+            ret = mmu6xx_get_physical_address(env, ctx, eaddr, access_type,
+                                              type);
         }
         break;