diff mbox series

[08/24] target/ppc/mmu_common.c: Introduce mmu6xx_get_physical_address()

Message ID ecd7263cc8a79479c4d85e9c12d1df8524a8b9f0.1713907038.git.balaton@eik.bme.hu (mailing list archive)
State New, archived
Headers show
Series Misc PPC exception and BookE MMU clean ups | expand

Commit Message

BALATON Zoltan April 23, 2024, 10:31 p.m. UTC
Repurpose get_segment_6xx_tlb() to do the whole address translation
for POWERPC_MMU_SOFT_6xx MMU model by moving the BAT check there and
renaming it to match other similar functions. These are only called
once together so no need to keep these separate functions and
combining them simplifies the caller allowing further restructuring.

Signed-off-by: BALATON Zoltan <balaton@eik.bme.hu>
---
 target/ppc/mmu_common.c | 32 ++++++++++++++++----------------
 1 file changed, 16 insertions(+), 16 deletions(-)
diff mbox series

Patch

diff --git a/target/ppc/mmu_common.c b/target/ppc/mmu_common.c
index c4fafebbe3..47346adb88 100644
--- a/target/ppc/mmu_common.c
+++ b/target/ppc/mmu_common.c
@@ -359,19 +359,25 @@  static int get_bat_6xx_tlb(CPUPPCState *env, mmu_ctx_t *ctx,
     return ret;
 }
 
-/* Perform segment based translation */
-static int get_segment_6xx_tlb(CPUPPCState *env, mmu_ctx_t *ctx,
-                               target_ulong eaddr, MMUAccessType access_type,
-                               int type)
+static int mmu6xx_get_physical_address(CPUPPCState *env, mmu_ctx_t *ctx,
+                                       target_ulong eaddr,
+                                       MMUAccessType access_type, int type)
 {
     PowerPCCPU *cpu = env_archcpu(env);
     hwaddr hash;
-    target_ulong vsid;
-    int ds, target_page_bits;
+    target_ulong vsid, sr, pgidx;
     bool pr;
-    int ret;
-    target_ulong sr, pgidx;
+    int ds, target_page_bits, ret = -1;
 
+    /* First try to find a BAT entry if there are any */
+    if (env->nb_BATs != 0) {
+        ret = get_bat_6xx_tlb(env, ctx, eaddr, access_type);
+    }
+    if (ret >= 0) {
+        return ret;
+    }
+
+    /* Perform segment based translation when no BATs matched */
     pr = FIELD_EX64(env->msr, MSR, PR);
     ctx->eaddr = eaddr;
 
@@ -1198,14 +1204,8 @@  int get_physical_address_wtlb(CPUPPCState *env, mmu_ctx_t *ctx,
         if (real_mode) {
             ret = check_physical(env, ctx, eaddr, access_type);
         } else {
-            /* Try to find a BAT */
-            if (env->nb_BATs != 0) {
-                ret = get_bat_6xx_tlb(env, ctx, eaddr, access_type);
-            }
-            if (ret < 0) {
-                /* We didn't match any BAT entry or don't have BATs */
-                ret = get_segment_6xx_tlb(env, ctx, eaddr, access_type, type);
-            }
+            ret = mmu6xx_get_physical_address(env, ctx, eaddr, access_type,
+                                              type);
         }
         break;