Message ID | 1498578321-13980-2-git-send-email-amelie.delaunay@st.com (mailing list archive) |
---|---|
State | Accepted |
Headers | show |
On Tue, Jun 27, 2017 at 05:45:13PM +0200, Amelie Delaunay wrote: > This patch replaces st,stm32-spi compatible with st,stm32h7-spi SoC > specific compatible and updates the example accondingly. Please use subject lines matching the style for the subsystem. This makes it easier for people to identify relevant patches.
diff --git a/Documentation/devicetree/bindings/spi/spi-stm32.txt b/Documentation/devicetree/bindings/spi/spi-stm32.txt index 3958bf6..415378b 100644 --- a/Documentation/devicetree/bindings/spi/spi-stm32.txt +++ b/Documentation/devicetree/bindings/spi/spi-stm32.txt @@ -7,7 +7,7 @@ from 4 to 32-bit data size. Although it can be configured as master or slave, only master is supported by the driver. Required properties: -- compatible: Must be "st,stm32-spi". +- compatible: Must be "st,stm32h7-spi". - reg: Offset and length of the device's register set. - interrupts: Must contain the interrupt id. - clocks: Must contain an entry for spiclk (which feeds the internal clock @@ -38,7 +38,7 @@ Example: spi2: spi@40003800 { #address-cells = <1>; #size-cells = <0>; - compatible = "st,stm32-spi"; + compatible = "st,stm32h7-spi"; reg = <0x40003800 0x400>; interrupts = <36>; clocks = <&rcc SPI2_CK>;