@@ -886,6 +886,8 @@ v9fs_stat2inode(struct p9_wstat *stat, struct inode *inode,
struct super_block *sb)
{
char ext[32];
+ char tag_name[14];
+ unsigned int i_nlink;
struct v9fs_session_info *v9ses = sb->s_fs_info;
inode->i_nlink = 1;
@@ -901,7 +903,22 @@ v9fs_stat2inode(struct p9_wstat *stat, struct inode *inode,
inode->i_uid = stat->n_uid;
inode->i_gid = stat->n_gid;
}
-
+ if ((S_ISREG(inode->i_mode)) || (S_ISDIR(inode->i_mode))) {
+ if (v9fs_extended(v9ses) && (stat->extension[0] != '\0')) {
+ /*
+ * Hadlink support got added later to
+ * to the .u extension. So there can be
+ * server out there that doesn't support
+ * this even with .u extension. So check
+ * for non NULL stat->extension
+ */
+ strncpy(ext, stat->extension, sizeof(ext));
+ /* HARDLINKCOUNT %u */
+ sscanf(ext, "%13s %u", tag_name, &i_nlink);
+ if (!strncmp(tag_name, "HARDLINKCOUNT", 13))
+ inode->i_nlink = i_nlink;
+ }
+ }
inode->i_mode = p9mode2unixmode(v9ses, stat->mode);
if ((S_ISBLK(inode->i_mode)) || (S_ISCHR(inode->i_mode))) {
char type = 0;